Fenix LR50R Operating Instructions Manual Download Page 1

Fenix LR50R Flashlight 

 

Technical Parameters 

ANSI/ 

PLATO FL1 

General Mode 

Functional Mode 

Turbo 

High II 

High I 

Med 

Low 

Eco 

Turbo 

Strob

SOS 

 

Output 

12000 

lumens 

6000 

lumen

3000 

lumen

1000 

lumen

350 

lumen

50 

lumen

12000 
lumen

6000 
lume

ns 

350 

lume

ns 

 

Runtime 

1hour 

50 

minute

s* 

2hour

s 20 

minut

es * 

2hour

s 40 

minut

es   

7hour

s 40 

minut

es   

24hou

rs 

58hou

rs 

1hour 

50 

minut

es * 

 

Distance 

950 

meters 

690 

meter

480 

meter

280 

meter

165 

meter

70 

meter

950 

meter

 

Intensity 

225750 

candela 

11840

candel

58200 

candel

19800 

candel

6850 

candel

1200 

candel

22575

candel

 

Impact 

Resistanc

1meter 

 

Submersi

ble 

IP68 

Note:  The  above  specifications  are  from  the  results  produced  by  Fenix  through  its  laboratory 

testing  using  the  Fenix  ARB‐L52‐16000  rechargeable  battery  pack,  under  the  temperature  of 

21±3°C and humidity of 50% ‐ 80%. The true performance of this product may vary according to 

different working environments and the actual battery used. 

*The Turbo, High II output are measured in total of runtime including output at reduced levels due 

to temperature or protection mechanism in the design. 

* The Turbo output will be 6000 lumens and the Strobe will be 3000 lumens when uses 21700 

Summary of Contents for LR50R

Page 1: ...1840 0 candel a 58200 candel a 19800 candel a 6850 candel a 1200 candel a 22575 0 candel a Impact Resistanc e 1meter Submersi ble IP68 Note The above specifications are from the results produced by Fenix through its laboratory testing using the Fenix ARB L52 16000 rechargeable battery pack under the temperature of 21 3 C and humidity of 50 80 The true performance of this product may vary according...

Page 2: ...ature at close range lighting Instant Turbo activation rapidly responds to emergency situations USB Type C charging and discharging interface supports PD3 0 PD2 0 QC3 0 QC2 0 fast charging protocols Battery level indication for instant checking of remaining battery level Made of durable A6061 T6 aluminum Premium type HAIII hard anodized anti abrasive finish Size 6 42 x 3 46 x 2 36 163 x 88 x 60 mm...

Page 3: ...itch to cycle through Turbo Strobe SOS Lockout Function Lock With the the light switched off and unlocked simultaneously press the two switches for 3 seconds the light will blink 2 times on Eco to indicate locked status Unlock With the light locked simultaneously press the two switches for 3 seconds the light will be activated on Eco In locked status clicking or pressing the switches will activate...

Page 4: ...eries are powerful cells designed for commercial applications and must be treated with caution and handled with care Only use quality batteries with circuit protection will reduce the potential for combustion or explosion but cell damage or short circuiting are potential risks the user assumes Battery Replacement Unscrew the light body to insert the battery with the anode side towards the light he...

Page 5: ...charging 2 The USB Type C port in the neck combines charging and discharging function 3 The light and the included charging cable support PD3 0 PD2 0 QC3 0 QC2 0fast charging protocols the external adapter will be auto detected if it supports the mentioned fast charging protocols if it does then 4 0A charging current will be selected or 2 5A charging current will be selected 4 Recharge a stored li...

Page 6: ... lumens within 60 seconds With the light switched on if High II is being selected for over 60 seconds the light will downshift until to 4000 lumens within 60 seconds Note The abovementioned functions are specially designed for avoiding discomfort and danger caused by overheating Overheat Protection The light will accumulate a lot of heat when used on High I High II or Turbo output level for extend...

Page 7: ... may cause the light to flicker shine intermittently or even fail to illuminate for the following reasons A The battery needs replacing Solution Replace battery Ensure batteryis inserted according to the manufacturer s specifications B The threads PCB board contact or other contacts are dirty Solution Clean the contact points with a cotton swab soaked in rubbing alcohol If the above methods don t ...

Page 8: ... All information provided in this manual is subject to change without prior notice ...