FENGJU | Innovative Signage Lighting | www.fjled
-
tech.com | Page 1
Components
1)
3x1.5mm
²
Power Cable
2)
Wire connectors
3)
#6 (M3) screws
4)
24V Power Supply
5)
Electronic grade silicone
RISK OF ELECTRIC SHOCK
Turn power off before inspection, installation or removal.
Properly ground power supply enclosure.
RISK OF FIRE
Use only UL certified wire for input/output connections. Minimum size 16 AWG (1.5mm
²
).
Follow all NEC and local codes.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING
Prepare Electrical Wiring
Electrical Requirements
•
Limited to use in dry and damp locations.
•
The grounding and bonding of the LED Driver shall be done in accordance with
National Electric Code (NEC) .
•
Follow all National Electric Codes (NEC) and local codes.
Layout Recommendations
Channel
Depth
(in.)
Single Row
Multiple Rows
Channel
Depth
(mm)
Single Row
Multiple Rows
Max.
Stroke
Module
Spacing
Row
Spacing
Module
Spacing
Max.
Stroke
Module
Spacing
Row
Spacing
Module
Spacing
4
8
6
2
6
100
200
150
150
50
5
9
6
2
6
125
225
150
150
50
6
10
7
3
7
150
250
175
175
75
7
11
7
3
7
175
275
175
175
75
≥
7
12
7
3
7
≥
200
300
175
175
75
*
Density guide designed to maintain a minimum of 600 lux for a single row or 800 lux for multiple
rows at sign face .
FLL Series Installation Guide