FEMA ELECTRÓNICA . Series S . S40-C1

19

Password

Version

Factory reset

Minimum

Brightness

Maximum

Standard

Left zeros

With left zeros

Without left zeros

Function 

counter (‘cn.1’)

Decimal point 

no

Counter configuration

  Multiplier 

x1

  Divider 

/1

 Preset 

0

  Mode 

up

  ‘FAST’ 

off

Sensor

  Pulls on channel A 

no pull resistor

  Pulls on channel B 

no pull resistor

  Pulls on reset 

pull-up

  Trigger 

2,5 Vdc

  Activation for channel A  on rising edge (‘on_h’)

  Excitation voltage 

5 Vdc

  Antirrebound filter 

0 mSeconds

Tools

  Fast access (Key UP) 

off

  ‘On Power Up’ 

    Delay 

0 seconds

  Key ‘LE’ 

reset function

  Memory of maximum 

-1999

  Memory of minimum 

9999

  Memory of cycles 

0

  Counter overrange 

flash

  Counter underrange 

flash

  Left zeros 

off

  Vexc. control 

off

  Password 

off

  Brightness 

3

Alarms 1 and 2

  Active 

off (disabled)

  Type 

maximum

 Setpoint 

1000

  Hysteresis 

0 counts

  Activation delay 

0.0 seconds

  Deactivation delay 

0.0 seconds

  Setpoint 2  

off

  On Alarm 

continue

  Inverted relay 

off

  Locked alarms 

off

Factory configuration for Ratemeter (‘cnF.6) and periodmeter (‘cnF.8) 

modes.

  Multiplier 

x1

  Divider 

/1

  Time windows 

0.5

  ‘SLOW’ mode

      tIME 

0 (off)

      nuMb 

1

  Recursive filter 

0 (off)

1.20 Full configuration menu (cont.)

1.21 

Factory configuration

Control Vexc.

with Vexc. error control

without Vexc. error control

Option

1

Configuration menu for the module installed at Opt.1

Option

2

Configuration menu for the module installed at Opt.2

Option

3

Configuration menu for the module installed at Opt.3

Summary of Contents for S40-C1

Page 1: ...with 4 digit display Fast access to alarm setpoints special modes for fast counting and for slow ratemeter applications on power up function configurable reading brightness Universal AC and DC power...

Page 2: ...15 Direct configuration for most usual sensor at the SnSr Auto menu see section 1 19 10 Function Trigger Sense helps to detect the correct trigger level see section 1 13 Multiple display filters memor...

Page 3: ...tor 1 to 9999 and configurable divider factor 1 to 9999 For low frequency applications the SLOW mode provides the best response time for each application see section 1 15 Maximum frequency up to 500 K...

Page 4: ...n sor parameters to the values indicated in the table The table also indicates the typical con nections for each type of sensor Param eters can be manually modified Connections are indicated for a sin...

Page 5: ...d control options relays analog outputs serial communi cations see section 2 Mechanical mounting panel connections plug in screw terminal housing material ABS polycarbonate V0 weight 150 grams front s...

Page 6: ...restart power up or configuration change is used for internal initialization and will not be counted as impulse 1 14 Function cycle counter 1 15 SLOW mode The trigger level is automatically configured...

Page 7: ...ENTER key It selects and accesses the menu option currently dis played At menus with numerical value entries it validates the num ber displayed Key UP 5 the UP 5 key gives access to the fast access me...

Page 8: ...e Impulses input at channel A Channel B disabled Access the Decimal point dP menu to select the decimal point position Move the decimal point by pressing the LE 3 key Configure the function mode selec...

Page 9: ...hen channel B is at logical state 1 Select on_0 to inhibit the counting when channel B is at logical state 0 1 19 4 Configuration for cnI 3 Configuration menu for mode counter control add substract cn...

Page 10: ...in formation on the SLoW mode in case of unstable signals activate the average filter AVr func tion It activates a recursive filter on the reading the filter is stronger for higher values from 0 0 to...

Page 11: ...the SLoW parameter configuring the tIME parameter between 1 and 1000 seconds Configure the nuMb parameter between 1 and 32 impulses See section 1 15 for more in formation on the SLoW mode in case of u...

Page 12: ...nnel Act r configures the activa tion of the reset channel by rising edge on_h or by falling edge on_0 Excitation voltage V EXc configures the value of the excita tion voltage at 5 Vdc 9 Vdc 15 Vdc an...

Page 13: ...s at Deactivation delay dEL 1 configure the delay to apply before alarm deactivation The deactivation delay starts counting when the setpoint value plus the hysteresis value is passed Value from 0 0 t...

Page 14: ...tpoint2 ALr2 function allows to visualize and modify the alarm2 setpoint through the fast access menu the Memory of maximum MAX or Memory of minimum MIn func tions allow to visualize the maximum or mi...

Page 15: ...et FAct menu select yes to load the default factory configuration for the instrument see section 1 21 1 19 20 Factory reset 1 19 21 Firmware version 1 19 16 Menus Overrange underrange The Counter over...

Page 16: ...unter inhibition Multiplier Divider Preset Preset value 1999 to 9999 Mode Up Down Inhibition Inhibits if chan nel B is high Inhibits if chan nel B is 0 Vdc Multiplier 1 to 9999 Divider 1 to 9999 Confi...

Page 17: ...3 wire PNP 2 wire PNP 3 wire Push pull TTL CMOS Pick up Inductive Vac 30 V Multiplier 1 to 9999 Divider 1 to 9999 Conf ratemeter Multiplier Divider Time window Seconds SLOW mode Average filter Filter...

Page 18: ...h To zero To preset Counter underrange Flash To zero To preset 1 20 Full configuration menu cont On alarm Continue To zero To preset Alarm 1 Setpoint Hysteresis Setpoint 2 Active Alarm type Alarms Act...

Page 19: ...ory of cycles 0 Counter overrange flash Counter underrange flash Left zeros off Vexc control off Password off Brightness 3 Alarms 1 and 2 Active off disabled Type maximum Setpoint 1000 Hysteresis 0 co...

Page 20: ...nt slide out of the housing To reinsert the instrument make sure that all modules are correctly connected to the pins on the display module Place all the set into the housing assuring that the modules...

Page 21: ...s and regulations 1 25 Warranty This instrument is warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date This warranty does not apply in case of misuse accident...

Page 22: ...pt 1 Power Signal A B C A B C The R1 module provides 1 relay output to to install at digital panel meters from Series S up to a maximum of 2 relays in a single meter Note for more than 2 relays per in...

Page 23: ...yed installation as it does not require soldering or special configuration Terminal A Vexc Terminal B Signal in mA or Vdc Terminal C GND Jumper M closed for mA Jumper V closed for Vdc For more informa...

Page 24: ...ration Terminal B B signal from RS 485 bus Terminal A A signal from RS 485 bus Terminal G GND For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_manual_en pdf Protocol Modbus RTU Functi...

Page 25: ...up to 31 modules Frames codified in represent able ASCII characters codes 32 to 255 directly visible using hyper terminal or similar programs Access to display values alarm status memory of maximum an...

Page 26: ...FEMA ELECTR NICA Series S S40 C1 26 Notes...

Page 27: ...FEMA ELECTR NICA Series S S40 C1 27 Notes...

Page 28: ......

Reviews: