2.- ADJUST AND CALIBRATION PROCEDURE

1.- Open the housing to access the instrument internal circuits
2.- Select apropriate jumpers on boards ME, MP and MS
3.- Connect signal generator to signal input terminals

Connect multimeter to signal output terminals

4.- Power up the instrument as indicated on the label
5.- Generate the signal level low

Operate potentiometer P1 on ME until indication shows desired signal output low level

6.- Generate the signal level high

Operate potentiometer  P2 on ME until indication shows desired signal output low level

7.- Repeat steps 6 to 9 in order to correct deviations and check adjust
8.- On model CCT-32, check excitation output voltage for transducers, 24 Vdc, maximum 25 mA

Weight

270 gr.

Wire Crossection

4 mm

2

 maximum

Housing and Cover

IP-40

Terminals

IP-20

Housing and Cover

Polycarbonate, Light Grey, RAL  7032, UL 94 V-1

Terminals

Polycarbonate, Dark Grey, UL 94 V-2

Mounting

Standard DIN rail (DIN 46277, DIN EN 50022)
(35 x 7,5mm) (1,38 x 0,3") .

1.- COMMON TECHNICAL SPECIFICATIONS

Output 0/20mA ó 4/20mA R

L

< 600 Ohms max. 22 mA ±3%

Output 0/10 Vdc

R

L

> 1000 Ohms max. 11 V ±3%

Response Time

 250 mSec

Galvanic Isolation

2  KV

eff. 

 50 Hz/1 min (between all circuits)

Isolation Test

4  KV

eff.

 50 Hz/1min

Accuracy

Class

 <

0,2 for CCT-32 and CCT-01

Class

 <

0,3 for CCT-04 and CCT-08

Ripple

 0,5 %

Pass Band

1,5 Hz (-3 dB)

Storage Temperature

-30 to +80 °C (-22 to +176 ºF)

Working Temperature

-10  to  +60 °C (+14 to +140 ºF)

Temperature Coef.

 0,015 %/ °C

Power Supply

See label on instrument

Consumption

<1,5 VA

MECHANICAL DIMENSIONS in mm (inches)

45

(1,771")

OUTPUTS / SALIDAS
        mA          Vdc

INPUT / ENTRADA

SU

PPL

Y /

 A

L

IM

EN

T

A

C

IO

N

3    4    5    6

9   10   11   12

7

1

+

Lo

H i 

+

-

-

75

(2,952")

110

(4,33")

36

(1,417")

CONVERTER-TRANSMITER

.- Serie CCT

CCT- 01 .- Signals in DC Voltage (Vdc)
CCT- 04 .- Signals in AC Current  (Aac)
CCT- 08 .- Signals in AC Voltage
CCT- 32 .- Signals in Process (mAdc)

13/96

rev.0911/03

P.I. Santiga Altimira 14 (Talleres 14, Nave 2)

E 08210-BARBERÀ DEL VALLÈS (SPAIN)

Tel:  (+34) 93.729.6004 Fax : (+34) 93.729 .6003

[email protected]        www.fema.es