background image

Page 6

KataEX-FM 

Assembly

Step #6: install lockout set screw(s), if desired

Default rotation of the fixed arm and motion arm is 360°. Installation of a lockout set screw limits rotation to 180°.

•  To lockout rotation of the fixed arm, install one of the M4x15 set screws in the underside of the arm stem. Tighten the screw, then back it off one turn.

 

— Installing a set screw in the front hole allows 180° rotation to the right only. A set screw in the rear hole allows 180° rotation to the left only. 

•  The fixed arm or motion arm must be in its allowed range of rotation when installing the lockout set screw. 

Step #7: organize cables and cords

•  Capture the cables and cords with the cable covers. Slide the cable covers as shown to attach them to the monitor arms.

•  Snap the cable clips onto the post and into the recessed groove above the base.

•  Route the monitor cables and power cords toward the rear by slipping the cords into the opening on the cable clips.

180°

front screw

rear screw

180°

front screw

rear screw

set screw

M4x15

2mm

Allen key

front

rear

capture

cables

with clips

snap on

cable clips

install covers over cables

slide in

slide in

slide

down

Summary of Contents for KATAEX1-DC-FM Series

Page 1: ...installation instructions Kata EX FM Model KATAEX1 DC FM ___ Model KATAEX1 GM FM ___ ___ SLV BLK or WHT single fixed motion monitor arm...

Page 2: ...your satisfaction Components and tools Additional tools required Phillips screwdriver Caution Hand tighten screws only Do not use power tools clamp or grommet mounting VESA plate screws 4 set screws 3...

Page 3: ...assembly to the worksurface in the desired position Be sure to tighten the clamp securely Place the base cover onto the mounting post and fit the cover over the base Step 1b attach base assembly to w...

Page 4: ...g ring Rotate the locking ring clockwise to secure it Step 3 attach VESA plate to monitor Remove the VESA plate from its VESA mount by 1 pushing forward the tab at the top and 2 lifting upward TIP Pra...

Page 5: ...he VESA plate to the VESA mount using one of the M4x15 set screws as shown below Step 5 remove cable management covers To remove the cable covers from the arm stem and fixed arm slide the covers outwa...

Page 6: ...to the left only The fixed arm or motion arm must be in its allowed range of rotation when installing the lockout set screw Step 7 organize cables and cords Capture the cables and cords with the cable...

Page 7: ...or rotation 3 Motion arm swivel adjustment Use the 4mm end of the dual Allen key to adjust the underside screw at the end of the fixed arm for the desired ease of monitor arm rotation 4 Fixed arm swiv...

Page 8: ...ranty and the purchaser s sole remedy is limited to the repair or replacement at ESI s option of the product or any defective part Costs such as installation labor fees or express shipping incurred du...

Reviews: