18
en
Changing the tool
Before mounting or replacing application tools or accessories, remove the bat-
tery.
This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
Mounting a grinding disc (figure 6).
Press the locking button only when the
motor is stopped.
Press the locking button completely through
and hold it in place. Loosen the clamping
flange.
Unscrew the clamping flange.
Replace the used-up grinding accessory
or insert a new one.
Pay attention that the grinding accessory
is properly centered between the sup-
port flange and the clamping flange.
Manually screw on the clamping flange again.
Press the locking button completely through
and hold it in place. Tighten the clamping
flange with the pin-type face wrench.
Note:
Pay attention to the mounting direction
of the clamping flange, which can vary
depending on the thickness of the grinding
disc.
WARNING
Fig. 6
ACCURATE
ACCURATE
2.
3.
3.
1.
1.
4.
5.
4.
4.
8.
6.
3.
3.
7.
Clamping flange