FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 66 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
10 Commissioning
Before starting the controller, check the electrical connections and the correct installation of the
plug-in cards. After commissioning, the operation of all the safety devices must be checked.
The settings are performed in dead man mode, i.e. press and hold the corresponding arrow key in
the corresponding direction until the desired position is reached.
10.1
… with absolute encoder or incremental encoder
1. 1
. Open CALIBRATE mode by briefly pressing the
STOP key.
!Eichen!
0 Start mit
"CALI:
2. 2
.
Approach door position CLOSED with the
CLOSE key and
save by pressing the
STOP key for approx. 3 seconds.
Zur Zupos.
à
0 Übern. mit
E
i
E
u
If the door moves in the incorrect direction: incorrect motor
rotary field! Switch off the controller and swap the 2 motor
connections. If the door does not move, the motor lacks
power. With the aid of the boost (performance increase at low
speeds) the motor can be supplied with an increase in power
(refer to chapter 10.5). Check the brake release.
Zur Zupos.
à
0 Übern. mit
E
i
E
u
3. 4
.
Move the door to the OPEN position by pressing the
OPEN
key and press the
STOP key for approx. 3 seconds.
Zur Aufpos.
à
xxx Übern. mit
E
i
E
o
If the door does not move, the motor lacks power. With the aid
of the boost (performance increase at low speeds) the motor
can be supplied with an increase in power. (see Chapter 10.5),
if necessary, check that the brake was released.
The pre-limit switches and ramps are automatically adjusted by the
subsequent travel of the door in automatic mode.
Aufpos. OK
~
Eo
~
4. 6
.
Press
briefly, the door moves down and is now taught in its
position.
Tor schließt
I.555 Lernfahrt
I.555
Zupos. OK
_
Eu_
5. 7
.
Now press
, repeat the process until the correction travel has
been completed. (Message I.510 = OK).
Tor öffnet
I.515 Korr. Fahrt
I.515
I.510 Korrek. OK
I.510
Tor öffnet
@AUF
Tor schließt
2
UF@