TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-L
FEIG ELECTRONIC GmbH
Page 45 of 71
FUZ2-A-B-C-CX-L_Montageanleitung_GB
_10.docx
9.3
… with light curtain TST LGB
Activating the TST LGB application
The application automatically sets several of the necessary function dependent parameters.
1.
Set application parameter A.480: to "1".
2.
Automatic range query:
Set the real light curtain distance per parameter P.44A in steps of 0.5 m.
The range must be set to correspond to the door width.
Open the door completely!
If the light curtain has been violated, the adjacent error
message will appear and the re-teach-in of all end
positions must be started again.
Zur Aufpos.
à
Hindernis T75
E
1
0
5
3.
Start the synchronisation by briefly pressing the
STOP-
key.
! Synchron. !
I615 LL angef.
I
615
SYNC:
4.
Open the door completely by pressing the
OPEN-key.
If the door moves in the wrong direction wrong
motor rotary field, switch parameter P.130 from 1 to 0
(change direction of rotation). If the door does not move,
the motor lacks power. With the aid of the boost
(performance increase at low speeds) the motor can be
supplied with an increase in power. (see Chapter 9.5), if
necessary, if necessary, check that the brake was
released.
Zur Aufpos.
à
I615 LL angef.
SYE
o
Zur Aufpos.
à
STOP - Keypad
E
05o
SYNC:
5.
Pressing the
STOP-key for approx. 3 seconds.
to save the OPEN position.
To Open Pos.
à
0 Übernahme mit
S
Y
E
o
6.
Press
STOP-key.
Zur Aufpos.
à
STOP - Keypad
S
Y
E
o
E
050
Zur Aufpos. ok
0
S
Y
E
o
Light line alignment is being requested.
LGx Qual. Test
S
Y
E
o
1. Start automatic teach-in of
CLOSE-position by pressing
the CLOSE-key.
! Synchron. !
0 Start with
S
Y
E
u
Automatic teach-in of the CLOSE position.
Door closes.
The detection range of the light curtain must be free,
otherwise the correction movement will be aborted and
the synchronization of the light curtain will be restarted.
Suche Si-Leiste
xxx Auto_Zu
S
Y
c
L
The display shows the messages in alternation: The door was
recognized in the CLOSE position and the light rays were taught-
in correctly.
!Korrekturfahrt!
xxx Start mit
I.515
!Korrekturfahrt!
I615 LL Abgl. ok
I.610