![Feig Electronic TST FUF2 Series Assembly Instructions Manual Download Page 35](http://html1.mh-extra.com/html/feig-electronic/tst-fuf2-series/tst-fuf2-series_assembly-instructions-manual_3883607035.webp)
TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 35 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
5.2 Motor and brake connections
Connect the shielding of the motor cable to the EMC bracket (for steel housings)!
Connect the shielding of the motor cable to the PE terminal.
For steel housings, also make direct contact between the shielding and the EMC
bracket.
To do this, remove a piece of the insulation of the motor cable and fix the shielding with
the clamp on the EMC bracket.
5.2.1 TST FUF2
3~
M
W
V
U
PE
T3
T2
T1
AC
~ ~
+
-
.
PE
PE
PE
Jumper
Connection example:
brake according to
open circuit current
control line including
brake connection and
limit switch connection
Shielding of the
motor cable
Brake rectifier
DC
Split ferrite
(742 727 22)
Split ferrite
(742 717 22 S)
30 31 32
L`
N`
L`
N`
Figure 12: Motor connection
When connecting the motor cable, the enclosed split ferrite (grey, Würth number: 742
727 22) must be placed around the three wires (T1/T2/T3).
We recommend to place another split ferrite (black, Würth number: 74271722S) as
close as possible to the door controller around the complete motor cable. The black split
ferrite is not included in the scope of delivery!