System-Manual
ID ISC.LR2000
FEIG ELECTRONIC GmbH
Page 29 of 184
H60700-3e-ID-B.doc
4.2. CFG1: Interface
The parameters of the CFG1 configuration block contains the data communication settings.
Byte
0
1
2
3
4
5
6
Contents
COM-ADR
0x00
BAUD
1
TRANS-
FORM
1
0x00
0x00
TR-
RESPONSE-
TIME
Default
0x00
0x08
0x01
0x00
0x00
38400 Baud
e,8,1
Byte
7
8
9
10
11
12
13
Contents
TR-
RESPONSE-
TIME
0x00
0x00
PROTOCOL-
SELECTION
SCAN-
INTERFACE
INTERFACE
READER -
MODE
Default
0xF0
0x01
0x05
0x00
1,2 sec.
COM-ADR:
(HostInterface.Serial.BusAddress)
Bus address of the Reader (0 .. 254) for communication via the asynchronous interface, es-
pecially for applications with the RS485 interface.
Notes:
Do not configure address 255!
Via the COM-Adr 255 in the send protocol, the Reader is able to be addressed at any
time. It answers then with the configured address.
1
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Reader
answers with STATUS = 0x11.