4.3. DIP Switch S1
4.3.1. Hardware Address setting
DIP switches 1 and 2 are used for setting the hardware address. Table 3 summarizes the settings
for the levels.
Table 3: Address setting
DIP switch S1
Level
1
2
3
4
-
-
not assigned (default)
-
ON
Level 1
ON
-
Level 2
ON
ON
Level 3
For further information see the corresponding manual
Communication FU UHF
(H80302-xe-ID-B).
NOTE:
Changed settings become valid only after pressing the reset button T1 or interrupting the
supply voltage.
4.3.2. DC Coupling
A DC-Offset can be supported on the antenna outputs OUT1 – OUT8. By default is this the supply
voltage. For future uses it is also possible to switch on a DC-Offset of +7 V. The maximum current
for all outputs is 150 mA.
DIP switch 3 is used for setting the DC offset for the antenna connections. Table 4 summarizes the
settings.
Table 4: DC offset
DIP switch S1
DC offset
1
2
3
4
-
12...24 V (supply voltage)
ON
7 V
NOTE:
Changed settings become valid only after pressing the reset button T1 or interrupting the
supply voltage.