![Feig Electronic ID ISC.MU02.02-CU Manual Download Page 52](http://html1.mh-extra.com/html/feig-electronic/id-isc-mu02-02-cu/id-isc-mu02-02-cu_manual_3882212052.webp)
OBID
i-scan
®
UHF
Manual
ID ISC.MU02.02
FEIG ELECTRONIC GmbH
Page 52 of 96
H90701-3e-ID-B
7.14. CFG37: Transponder Parameters UHF
The parameters of the CFG37 configuration block contain general Transponder settings.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
IDDIB
TID-LENGTH
Default
0x00
0x00
IDDIB: (Transponder.Miscellaneous.IdentifierInterpretationMode)
(Identifier Data Interpretation Byte)
:
Defines in which way the Reader interprets and display the Identifier data read during in-
ventory process.
0x00 – automatic Mode (IDD Type is automatic set by the Reader)
0x02 – EPC and TID (EPC and TID are combined to one serial number)
NOTE:
If IDDIB is 0x02 then only the TID must be used to address commands (e.g. read, write...) to
the tag
TID-LENGTH: (Transponder.Miscellaneous.TID-Length)
Defines the length of the TID to be expected when IDDIB is EPC and TID.
0x20 – 32 Bits
0x40 – 64 Bits
0x60 – 96 Bits