7.9. CFG10: Trigger
The configuration block contains parameters for the trigger configuration.
Byte
0
1
2
3
4
5
6
Contents
TRIGGER-
MODE
TRIGGER-
USE-A
TRIGGER_1-HOLD-TIME
0x00
TRIGGER_2-HOLD-TIME
0x00
TRIGGER_3-
HOLD-TIME
MSB
Default
0x00
0x00
0x0005
0x0005
0x00
500ms
500ms
Byte
7
8
9
10
11
12
13
Contents TRIGGER_3-
HOLD-TIME
LSB
TRIGGER_4-HOLD-TIME
TRIGGER_5-HOLD-TIME
TRIGGER-
USE-B
0x00
Default
0x05
0x0005
0x0005
0x00
500ms
500ms
TRIGGER-MODE
defines the mode of the scanner.
Bit
7
6
5
4
3
2
1
0
Function
Trigger
0
Condi-
tion
0
0
0
0
Unlimited
Valid Time
Trigger:
(OperatingMode.BufferedReadMode.Trigger.Enable)
(OperatingMode.NotificationMode.Trigger.Enable)
(OperatingMode.ScanMode.Trigger.Enable)
b0:
Trigger disabled:
The Reader RF Power is on and the Reader scans all the time in BRM
Mode.
b1:
Trigger enabled:
The Reader start the RF Power and the scan, if the trigger is activated
by the external switch.
NOTE:
If Trigger is enabled and not activated by the external switch, the RF-field will be switched