5.4.1 Reader Setting for Indicator
The ISOStart software can be used to set the Reader configuration so that output 1 X6-1/-2 or
relay X11 opens or closes when a Transponder is read.
Step
Action
Note
1
Start ISOStart Software
2
Sel
ect “Configuration” and
click on “Read” to read the
complete configuration.
3
Operating Mode
Select Buffered Read Mode.
4
Digital IO:
Output Idle Mode: OFF
Idle Flash Mode: 1Hz
Setting Time:
with „Setting Time“ set
time of relay for alarm du-
ration.
(10 x 100ms = 1 second)
Assign Relay 1 and Output
1 to antenna 1-4
. „True“
means that Relay 1 will be
active at a read trans-
ponder.
5
Set by clicking on „Apply“.
6
Transponder
ISO 15693
–Selection Mask
„Enable AFI“-Enabled
Enter desired value in
“AFI 1” field.
(e.g. 01)
6
Set by clicking on „Apply“