Feider Machines FGHI7000ES User Manual Download Page 1

ORIGINAL INSTRUCTIONS >EN

PETROL INVERTER GENERATOR

FGHI7000ES

USER GUIDE

CAUTION: Read this manual before using this machine!

Summary of Contents for FGHI7000ES

Page 1: ...ORIGINAL INSTRUCTIONS EN PETROL INVERTER GENERATOR FGHI7000ES USER GUIDE CAUTION Read this manual before using this machine...

Page 2: ...BEFORE OPERATION 10 6 START THE ENGINE 13 7 OPERATING THE GENERATOR 15 8 SHUT OFF THE ENGINE 20 9 MAINTENANCE 20 10 TRANSPORTATION WAREHOUSING 24 11 TROUBLESHOOTING 25 12 SPECIFICATIONS 27 13 CIRCUIT...

Page 3: ...as this can get caught in the machinery as it runs Use safety equipment Wear protective gear such as an anti dust mask non slip safety shoes a helmet or hearing protection Stay vigilant watch what yo...

Page 4: ...cause burns Pay attention to the warnings on the generating set Engine exhaust gases are toxic Do not operate the generating set in unventilated rooms When installed in ventilated rooms additional req...

Page 5: ...t and that they are used correctly The connection of a generator used for auxiliary power to the electrical installation of a building must be performed by a qualified electrician and in conformity to...

Page 6: ...n Fill in engine oil It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death This symbol indicates the surface is very hot and no...

Page 7: ...ther the battery is losing electricity Standard voltage 12V 13 5V If the battery voltage is too low please recharge it with the battery charger Charge for 3 hours or until full disconnect the battery...

Page 8: ...tor control panel Turn off Generator Note Turn the ignition key to OFF position the generator will stop immediately in any condition 1 Turn off the generator in the following instructions Turn off and...

Page 9: ...ise incorrect operation could result in personal injury or equipment damage 3 SAFETY LABEL POSITION These decals indicate serious accident that you may cause Please read the decals safety precautions...

Page 10: ...EFORE OPERATION The generator should be placed on a flat ground without debris around and at least 1 meter away from buildings and other equipment BE CAUTIOUS Be sure to check whether the generator is...

Page 11: ...osity grade as follows Loosen the screw on the side maintenance cover to remove the cover Remove the oil dipstick wipe the dipstick with a clean cloth insert it into the oil port without tightening th...

Page 12: ...el when the generator is running EXTREMELY DANGEROUS Do not overflow the fuel tank no fuel above the neck Tighten the fuel tank cap after refueling BE careful not to spill fuel when refueling due to s...

Page 13: ...gh voltage the generator will not be able to use the electric start or remote start You can only use the recoil start to start the engine Loosen the screw on battery cover and remove the cover Connect...

Page 14: ...sure the engine does not turn off when pushing inwards BE CAUTIOUS Never allow the starting handle to rebound Slowly put it back When pulling the cable hold the generator tightly to prevent the gener...

Page 15: ...source If the unit is used as a backup power source for a building the connection of the generator to its power system shall be carried out by a professional electrician and must comply with the appl...

Page 16: ...the generator If the generator is overloading or the connected device is internally faulty the LCD displays Overload and there will be no power output You must shut the generator off to stop the gener...

Page 17: ...d the pure inductive load cannot exceed the rated power of the generator The power can only run 40 to 75 of rated power on pure inductive load Model FGHI7000ES Rated Power W 6300 Frequency Hz 50 Power...

Page 18: ...exceeds 16V the charge must be stopped immediately otherwise the battery burns or explodes Start the generator as the above instruction Connect the charging cable to the generator DC socket and conne...

Page 19: ...th magnesium oxide and seek medical care Batteries and electrolytes should be placed where children are not accessible DC protector When using AC power you can use DC output at the same time The DC ci...

Page 20: ...for recoil start Turn the fuel switch to OFF position When not using the generator for a long time please turn off the generator 9 MAINTENANCE Maintenance and adjustment schedules are developed to ke...

Page 21: ...l In areas where pollution is severe check and repair frequently The above regular maintenance schedule is calculated at ambient temperature of 25 C If the ambient temperature exceeds 30 C reduce the...

Page 22: ...you use the generator in a particularly dirty place you need to keep the maintenance regularly WARNING Do not use gasoline or low ignition solvents to clean the generators because they are flammable a...

Page 23: ...g Measure the spark plug clearance with a feeler gauge and the spark plug clearance should be 0 6 0 7mm 0 024 0 028 in Install the spark plug carefully Be careful of the thread dislocation After insta...

Page 24: ...n to install the outlet cover plate back 10 TRANSPORTATION WAREHOUSING To prevent fuel leakage during transport or temporary storage turn off the oil switch and place the generator in a location where...

Page 25: ...linder pull the start handle a few times to scatter the oil and then install the spark plug back Pull the handle slowly until it feels pressure At this moment the piston is rising to the top of its co...

Page 26: ...l is added or the oil is changed the oil alarm indicator flashes when pulling the start handle at this time the generator should be shaken back and forth to ensure that the float of the oil alarm floa...

Page 27: ...sound power level 96 dB A Generator set AC out put Voltage 230 V AC Frequency 50 Hz AC rated output power COP 6 3kW AC max output power 7 0kW AC Rated current 27 4A Power factor cos 1 0 Performance cl...

Page 28: ...13 CIRCUIT DIAGRAM 28...

Page 29: ...erds Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature Machinery Directive 2006 42 EC EMC D...

Page 30: ...he user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifcations without notice Consequently the product may be diferent from the information co...

Page 31: ...pairs will be done by approved engine manufacturers of these manufacturers see their site http www briggsandstratton com eu fr http www honda engines eu com fr service network page jsessionid 5EE8456C...

Page 32: ...sary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair stat...

Page 33: ...BUILDER SAS 32 rue Aristide Berg s Z I du Casque 31270 Cugnaux France MADE IN PRC...