Page 22 of 40
11.2.3
Adjusting the set point
The set point is what determines how cold the display case will hold food and beverage. To adjust the
set point press and hold the wrench button until the display begins to flash a number (three seconds).
Then use the up and down arrows of the keypad to scroll through the set point options. There are nine
(9) available set points, the higher the number of the set point name, the colder the display case will
run, with setting “9” being the coldest and setting “1” being the warmest.
Once you have chosen your
desired setting press the wrench button again to confirm your choice.
11.2.4
Entering manual defrost mode
In order to initiate a manual defrost press and hold the red down arrow for 3s. The control will read
“dEF” while the button is being held. The defrost
is initiated when the orange snowflake appears on
the control display.
11.2.5
Error codes
It is possible for error codes to be displayed on the control screen. In the event of a malfunction an
alarm will sound and a red ringing bell will be displayed on the screen. An error code or codes will flash
intermittently on the display. If there are multiple codes, the display will continuously cycle through
them.
The following photo shows error code “E0” as an example next to the red bell.
You may mute the alarm by pressing and releasing the wrench button. The red ringing bell and all error
codes will still be displayed. When the fault is remedied the control will return to normal operation and
will automatically clear the codes from the display.