CONDITION
Unit Noisy
(Non-Refrigerated)
If equipped, check ventilation fan motor and blade for obstruction, change as
necessary.
Unit Noisy (Refrigerated
Only)
Close proximity to the counter, vaulted ceilings, tile and overall open floor plan
as well as grouping equipment together can all amplify unit “noise”
Check that the condensing coil is not restricted.
Check the evaporator and condenser fan blades are not hitting anything.
Check panels for loose fasteners and bent panels that can allow for vibration.
Check refrigeration lines and condensing unit for vibration.
Check compressor for any abnormal noises.
Lights Not Working
Check that the light switch is on.
Shelf lights – lamp cord must be fully seated into receptacle, gently tap them in
with a rubber mallet if needed to make full contact. Check that the lamp cord is
plugged into the end of the LED light strip. – Replace light if necessary.
Check power AC input voltage at LED driver.
Check to DC output voltage at LED driver.
If no output, disconnect output from unit wiring harness and try again as LED
driver will put itself into protect mode if output harness has a short. – Replace
driver if necessary.
NOISE AND LED LIGHTS
FCC / FCCR CHOCOLATE and CONFECTIONARY CASE
NON-REFRIGERATED / CLIMATE CONTROLLED
2