I N S T A L L A T I O N 

     Omega 90 Amplifier 

 

                     

 

 
 
 
 
 
 
 
 
 
 
 

22-U90-00 
ECO# 104-06-MAN 

             

FS UNITROL • 1108 RAYMOND WAY • ANAHEIM, CA 92801 • (714) 871-3336 • (800) 854-3375 • FAX (714) 871-3418 

 

Summary of Contents for Unitrol Omega 90

Page 1: ...I N S T A L L A T I O N Omega 90 Amplifier 22 U90 00 ECO 104 06 MAN FS UNITROL 1108 RAYMOND WAY ANAHEIM CA 92801 714 871 3336 800 854 3375 FAX 714 871 3418 ...

Page 2: ...GE I General Information 1 II Changing Pre Set Sounds 2 III Installing One 1 Amplifier 3 IV Installing Two 2 Amplifiers 4 V Adjusting P A Loudness 5 VI Safety Message To Operators 6 VII Safety Message To Installers 7 i ...

Page 3: ...rial and or workmanship UNITROL UNITROL will complete the necessary repairs under warranty This warranty does not cover travel expenses the cost of specialized equipment for gaining access to the product or labor charges for removal and re installation of the product Lamps flash tubes or batteries are not covered under warranty Warranty will not be extended to any unit that has been subjected to a...

Page 4: ...unds your system will actually produce depends on the Controller used with the Amplifier and sound selections made within the Amplifier A special siren loud tone is built into the amplifier to serve as a burglar or high temperature alarm Activated by existing door and trunk switches the alarm tone occurs when an unauthorized person opens a door or trunk In a K9 carrier a heat sensing switch can ac...

Page 5: ... 2 is set for WAIL and YELP only Siren 2 will then emit only the standard WAIL and YELP sounds while Siren 1 emits the maximum sounds Mark one amplifier 2 on the faceplate and make these changes Set only these switches ON Switch 2 group 1 Switch 3 group 1 Switch 1 group 2 Switch 2 group 2 Switch 8 group 2 Set all other switches to the OFF position 7 SIREN QUIETING To protect your hearing as well a...

Page 6: ...r or trunk within 8 seconds prevents operation of the alarm This allows for normal vehicle exit and entry when system is armed Existing door switches trunk switch or motion detector and or heat sensing switch Unitrol part number UTAS can be used for triggering the alarm Any switch must emit a ground when activated CAUTION Interconnection of a heat sensing switch or motion detector with door and tr...

Page 7: ...screws above wire openings Use Minimum wire sizes indicated CAUTION The sources of Primary wires Must connect exactly to the same point Example The source for Bat terminals of amplifier 1 and 2 must be connected to the same point Failure to observe this precaution will result in erratic siren performance of either or both amplifiers and or noise over the siren speaker during public address functio...

Page 8: ... 9000 Omega Controllers 2 MICROPHONE LOUDNESS With a louder than average voice make a mic test count while increasing Amplifier gain rotate clockwise Rotate until squeal occurs then rotate slightly counter clockwise until squeal stops a Repeat test while standing outside the vehicle not necessary when installing Series 8000 or 9000 Omega Controllers 3 RADIO TAPE LOUDNESS Loudness of amplified call...

Page 9: ... maximum sound output Signaling Limitations Be aware that the use of your visual and audible signaling devices do not give you the right to force your way through traffic Your emergency lights siren and actions are REQUESTING the right of way Although your warning system is operating properly it may not alert everyone People may not hear see or heed your warning signal You must recognize this fact...

Page 10: ...ound connection must be made to a solid chassis component and not to an insulated point Sound output will be severely reduced if any objects are in front of this speaker If maximum sound output is required for your application you should ensure that the front of the speaker is clear of any obstruction Install the speaker s in a location which provides maximum signaling effectiveness and minimizes ...