![Federal Signal Corporation UltraVoice UVIC Description, Specifications, Installation, Operation, And Service Manual Download Page 19](http://html1.mh-extra.com/html/federal-signal-corporation/ultravoice-uvic/ultravoice-uvic_description-specifications-installation-operation-and-service-manual_3832936019.webp)
19
Specifications
Description, Specifications, Installation, Operation, and Service Manual
Specifications for the UVARM
Table 14 Electrical for the UVARM
Current Draw
< 200 mA
Balanced 33 ohm output
Adjustable from 0.2-1.9 V
RMS
Balanced 600 ohm output Adjustable from 0.2-3 V
RMS
or -12 to +11 dB, surge protected
Single-ended or balanced
Line-level/600 ohm output
Adjustable from 0.2-3 V
RMS
Relay outputs
4 SPDT
Contact rating
20 A at 30 Vdc with NO and NC contacts
Specifications for the UVLOC
Table 15 Specifications for the UVLOC
UVLOC Operating Voltage
20-32 V dc
Current Draw
< 25 mA
UVLOC Interface Module
20-32 V dc
Operating Current
< 50 mA
ARM Input
0-5 Vdc, 5 Vdc = ARMed
ARM Output
7.4-8.0 Vdc Not ARMed, 20-32 Vdc ARMed
Audio Output
600 ohm balanced, adjustable 700 mV
P-P
to 5 V
P-P
Installation Specifications
Maximum distance between
UVLOC and UV Controller
Approximately half mile of cable, </=200 ohms of cable
Maximum Number of UVLOCs
per UV Controller
6 (unless optional card is ordered)
External wire management required
UV Control Panel
Interface Cable
CAT5, 4 pairs
Operating Temperature
Indoor use, non condensing humidity
-22°F to 149°F/-30°C to 65°C
Size (H x W x D)
10 x 4.75 x 3 inches maximum
25.4 x 12.1 x 7.6 cm
Specifications for the Serial to Network PCB
Table 16 Electrical for the Serial to Network PCB
Current Draw
< 150 mA
Table 17 Physical for the Serial to Network PCB
Dimensions (H x W x D) ~ 2 in x 4 in x 6.5 in
Weight
< 2 lb
Table 18 Network Port
Protocol
IEEE 802.3, 10 Base-T connection