![Federal Signal Corporation UltraVoice UVIC Description, Specifications, Installation, Operation, And Service Manual Download Page 15](http://html1.mh-extra.com/html/federal-signal-corporation/ultravoice-uvic/ultravoice-uvic_description-specifications-installation-operation-and-service-manual_3832936015.webp)
15
General Description
Description, Specifications, Installation, Operation, and Service Manual
any data coming into the serial port is converted to TCP/IP data packets and sent out
over the network port to the server’s IP address. The unit also contains a digital to analog
converter. This allows specially configured incoming data packets to be converted to
audio, which is then filtered and sent out over a 600-ohm audio port.
UVIC Backplane Motherboard
The UVIC backplane motherboard provides the electrical connections between the UV+
Control board, the Audio and Relay output board, and the UV400 amplifiers. In addition,
it provides connections for field wiring and relay outputs.
The UVIC backplane motherboard is limited to two amplifier slots or one amplifier if
used with the UVIC25ST.
The UVIC backplane motherboard has a fused normally open relay output. The relay is
normally programmed to close while a control function is active. An LED indicator turns
on when the relay is active.
Commander Software System (SFCDWARE)
Commander is software used to control, monitor, and configure the siren controller. The
programming software communicates with the siren controller over the communication
link. Refer to the Help menu provided with the software for operational details.
Ordering Information
Table 1 Ordering UVIC
UVIC Model/
Part Numbers
Description
UVIC
No Radio (RF), 120 V
UVICH
Two-way VHF (134-174 MHz)
UVICU
Two-way UHF (400-470 MHz)
(450-512 MHz, optional)
UVIC-IP
IP-enabled
*
UVIC-LL
Landline
UVIC240
UVIC with 240 Vac transformer, No Radio
*
Requires IP Networking Software
Table 2 UVIC Accessories
UVIC
Accessories/
Part Numbers
Description
DVSD
Digital voice mini SD card: 4,093 messages, 17 hours
DVR
Digital voice recording fee per 16 messages
UV400
400-watt Amplifier
SFCD*
Commander Software System,*10, 25, 255, or 512 Site License
TB-LL
Telco base, landline communication interface
UVARM
UltraVoice Audio Relay Module