Restoring Configuration to Factory Defaults
You can restore the factory default settings with or without restoring the network
parameters. The Activation Button configuration will not change when a Factory Default is
performed.
The RTU must reboot to begin using the new settings. Use the Reboot web page to
reboot the RTU.
Default Settings
RTU Number: 900
Description: my description
SmartMsg disabled
Modbus disabled
Smartmsg Server: 10.10.10.10
IP Address: 10.10.10.1
Subnet Mask: 255.255.0.0
Default Gateway: 10.10.10.10
Primary/Secondary DNS: 0.0.0.0/0.0.0.0
Admin user name: admin
Admin user password: fedsig
User 1 - User 4 username/password: blank
Factory Support User: Enabled
To restore configuration to factory defaults:
1. Select Factory Defaults.
The Factory Defaults page appears.
Field
Description
Include Network
Parameters
Check the box to include network parameters.
NOTE:
This changes the IP address of the RTU to factory
default settings and make the device inaccessible over a
production network.