SmartSiren Platinum Convergence Network
Federal Signal www.fedsig.com
Connecting the Convergence Network
18
Overview of the Convergence Network Connections
The Convergence Network system has these types of connections via cables and
locking connectors included with the kit. See Figure 4.
Connections for the siren amplifier/relay module:
• Three “plug and play” serial ports that communicate on the Federal Signal
Convergence network with the control head, compatible light bars, and the
Federal Signal Model 660100 Relay Module/Two-Channel Flasher.
• Seven to ten 10 A auxiliary solid-state relays (cable assembly 1751541)
• Four low-current auxiliary solid-state relays and a Park Input circuit (cable
assembly 1751542-01 or 1751542-NY)
• SignalMaster™ directional warning lights (cable assembly 1751542-01,
SSP3000B only)
• Four auxiliary relay inputs (cable assembly 1751542-01 or 1751542-NY)
• Speakers and a horn ring circuit (cable assembly 17500307)
• Power terminals for negative ground and positive 12 Vdc
Connections for the control head:
• Four active-low input circuits that activate when pulled to ground. They can
be configured to operate with the SSP3000B system control head or with the
switches on the steering wheel of the Ford Police Interceptor.
• Connections to the siren for battery ground (-GND) and +12 Vdc switched by
ignition
• Connection for the Federal Signal public address microphone (P/N 258B577-
03)
• Convergence Network 25-foot cable that connects the control head to the
siren amplifier (1751532)
• Optional ignition input to run long timers
For installation details, see “Connecting the Control Head” on page 32.
For instructions on configuring the operation of the devices connected through the
Convergence Network, see the “Convergence Configuration Software Manual” P/N
2562418.