![Federal Signal Corporation PAGASYS GEN II P-SYS-G Description, Installation, Operations And Maintenance Manual Download Page 49](http://html.mh-extra.com/html/federal-signal-corporation/pagasys-gen-ii-p-sys-g/pagasys-gen-ii-p-sys-g_description-installation-operations-and-maintenance-manual_548461049.webp)
49
I/O and Terminal Block Cards
Description, Installation, Operations, and Maintenance Manual
Federal Signal www.fedsig.com
Figure 25 Fan Control and Monitoring Card (P-FCMC-G)
3.5.1 Fan Control and Monitoring Card Specifications (P-FCMC-G)
Table 31 Environmental and Physical for the Fan Control and Monitoring Card
(P-FCMC-G)
Operating Temperature
-25 to +55
°
C
Humidity
0-98% non-condensing
P-FCMC-G Dimensions (H x W x L)
44 mm x 200 mm x 124 mm
Weight
0.20 kg/0.43 lb
Table 32 Temperature Measurement
Measurement range
-30 to +100ºC
Measurement Circuit Accuracy
±1ºC
Temperature sensor Tolerance at 25ºC
±1%
Table 33 Fan Power Supply
Fan AC supply input voltage range
85–264 Vac
Input current with 110 V supply
< 600 mA AC
Input current with 230 supply
< 400 mA AC
Fan AC input fuse rating
1.6 A
Fan DC supply output range
24-55 V DC
Typical Fan current at 48 Vdc
1.2 A
Card Fan fuse hold current
1.85 A
Fan control Relay contacts ratings
10 A