1. Configuring the Network Interface
Setup, Configuration, and Operation Manual
Federal Signal
www.fedsig.com
Restoring Configuration to Factory Defaults
You can restore the factory default settings with or without restoring the network
parameters.
Default Settings
RTU Number: 1
Description: my description
SmartMsg disabled
Modbus disabled
Smartmsg Server: 10.10.10.10
IP Address: 10.10.10.1
Subnet Mask: 255.255.0.0
Default Gateway: 10.10.10.10
Primary/Secondary DNS: 0.0.0.0/0.0.0.0
Admin user name: admin
Admin user password: fedsig
User 1 - User 4 username/password: blank
Factory Support User: Enabled
To restore configuration to factory defaults, do the following:
1.
Select Factory Defaults.
The Factory Defaults page appears.
Fields
Description
Include
Network
Parameters
Check to include network parameters. NOTE: This changes the IP
address of the RTU to factory default settings and makes the device
inaccessible over a production network.
Apply
Restores your settings to the factory defaults. NOTE: Your current
settings will be overwritten.
2.
Click Apply restore your settings to the factory defaults.
3.
Reboot the device for the changes to take effect.