11
Installation
Description, Specifications, Installation, and Operation Manual
Federal Signal
www.fedsig.com
Figure 2 Rack Mount Dimensions
1.70"
0.41"
18.98
18.28
1.25"
14.18
6.06"
Connect each Informer-PA to the LAN using CAT5 cable. If the Wired Ethernet has PoE, no
other power connection is required.
If PoE is not available, run the supplied external AC/DC power supply against the wall and
plugged into a 120 Vac, 60 Hz outlet. Plug the low-voltage end of the cord into the power
jack located at the rear of the Informer-PA. Route the cord to ensure it is protected against
walking on, tripping over, or pinching the cord.
Wall Mounting
The Informer-PA can also be wall mounted by moving the mounting brackets. Before
mounting the unit, determine a suitable location considering the criteria listed. Ensure
the screws are placed into material that can adequately support the weight of the
Informer-PA. The maximum bolt diameter that fits the bracket slot when mounting to
drywall is #12. Ensure that the screws are tightened sufficiently to securely fasten the
Informer-PA against the wall.
Figure 3 Attach Bracket