13
Installation
Description, Specifications, Installation, Operation, and Service Manual
Federal Signal
www.fedsig.com
Preliminary
Carefully inspect the unit for damage that may have occurred in transit. If there is any
physical damage to the unit or components, notify the carrier immediately, stating the
extent of the damage.
Installation Requirements
INSTALLATION PRECAUTIONS: Use good installation methods and follow local
ordinances for mounting cabinet.
Mounting on a Pole
The 2001-AC components are typically mounted on a pole. A typical installation showing
the relative location of the controller is illustrated in Figure 2. There are numerous
methods to use to mount the 2001-AC components. In all cases, the installation must be
rigid, secure, and free from physical shock or vibration.
Mount the Contactors Enclosure and Transformer/Rectifier separately. There are predrilled
mounting holes in each enclosure.
To attach the Contactors Enclosure and Transformer/Rectifier to the pole:
1. Use proper lifting equipment to lift the enclosures to the desired height along the
pole. Attach the Contactors to the pole at a height accessible to service personnel
but discourages vandalism.
2. Use the proper lifting equipment to hold the components against the pole. Using the
holes in each enclosure as a template, locate the holes on the pole.
Transformer/Rectifier
3. Transformer/Rectifier—Drill a 3/8-inch hole at all mounting locations. Drill each hole at
least 3-1/2 inches (90 mm) deep.
4. Attach the Transformer/Rectifier Enclosure to the pole; use a minimum of three
user-supplied 1/2 by 5 inch lag bolts. Slide a user-supplied 1/2-inch flat washer onto
each bolt before threading the bolt into the pole.
Contactor Enclosure
5. Contactor Enclosure—Attach the enclosure to the pole using four user-supplied 1/4 by
3 inch lag bolts. Be careful not to bend the enclosure around a small diameter pole.
6. Mount a user-supplied fused disconnect switch, per local and national electric codes,
on the pole beneath or opposite the Transformer/Rectifier assembly in line with the
primary AC service.