FEC Remote Lighting Controller V4 HP0832
User Installation and Operation Manual
© Interleader Ltd 2020
38 of 64
26/08/2020
8.9 Unit History and Status
Unit History & Status provides:
Unit History
– Maxima and minima
Unit Status
– Current status, and
Unit History
Products build a history log for diagnostic purposes and is a read-only
function.
Data returned includes:
1) the maximum and minimum supply voltage detected
2) the maximum and minimum temperature of the system
3) the number of times the product has been activated (turned
on), and
4) the total running time of the RLC in hours and minutes
Unit Status
Absent from the current release of SMS
UHF Radio Setup
Non-standard product to special order. Will normally report
‘Not Fitted’
VHF Status
The VHF status command reads the VHF receiver parameters. The
frequency, threshold, click period and space/mark ratio are all as set
in the Program menu.
Also displayed is the Received Signal Strength. This is a very useful
way, in conjunction with the refresh button, of understanding the
performance of the radio and is a vital aid to setup, testing and
subsequent validation.
Wired Interface Status
This menu shows the status of the Inputs (switch or relay circuits) and
again is extremely useful during installation and testing as well as
monitoring the satus of the inputs.
Press refresh to get the current status.