FDC ENIGMA II SLIMLINE Owner'S Manual Download Page 17

LT4934 (1:01/08) 

17 

ENIGMA II SLIMLINE 

Maintenance Instructions

 

 

SECTION ELEVEN  

Maintenance 

 

• 

Servicing  should  be  carried  out  annually  by  a  competent  person  such  as  a  CORGI-
registered person in accordance with the relevant regulations, to ensure the safe and correct 
operation of the appliance. 

• 

Before commencing any service or replacement of parts, turn off the gas supply to the fire.  
After servicing check for gas soundness. 

• 

When  ordering  spare  parts  please  quote  appliance  name  and  serial  number  these  can  be 
found on the data badge, which is located by removing the decorative fire trim.  

• 

At least once a year, check for debris in the catchment area behind the fire and in the flue 
way. 

• 

If  soot  has  accumulated  check  to  establish  cause,  rectify  and  clean  flue  or  chimney 
accordingly. 

• 

Examine the coals or pebbles for signs of cracking and replace if necessary. IMPORTANT: - 

REFER TO THE ‘HEALTH & SAFETY NOTICE LOCATED ON PAGE 4 OF THIS BOOKLET 
BEFORE  CLEANING  OR  REPLACING  ANY  REFRACTORY  MATERIAL

.

  Refer  to  coal  or 

pebble layout procedure (pages 5 & 7) before attempting to replace coals or pebbles, which 
should only be replaced as a complete set with no extra coals or pebbles added.  

• 

Check  pilot aeration holes for  linting;  use a vacuum  cleaner  to  remove  any  lint  taking  care 
not to damage the pilot head. 

 

Replacement of Gas Control

 

1. 

Turn off the gas supply by the isolating cock. 

2. 

Remove fire fret. 

3. 

Remove all loose coals or pebbles. 

4. 

Remove moulded refractory parts except back board which can stay in place. 

5. 

Disconnect slide control mechanism. 

6. 

Remove 4 screws fixing burner tray into the casing. 

7. 

Disconnect fire at inlet elbow and remove burner tray from the casing. 

8. 

Undo  the  three  compression  nuts  securing  the  pipes  to  the  gas  valve  and  remove  the 
thermocouple connection together with wires from the ignition switch. 

9. 

Clean, service or replace gas valve. 

10. 

Re-assemble the in reverse order. 

11. 

Turn on the gas supply, check for soundness and re-commission appliance. 

 
 
 
 
 
 

Summary of Contents for ENIGMA II SLIMLINE

Page 1: ...LUDES USER INSTALLATION MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in...

Page 2: ...und 13 Clearances at Side of Fire 13 SECTION NINE To Install the Appliance 14 Checking the Flue and Fire Opening 14 Connecting the Gas Supply 14 Concealed gas connection from the rear 14 Visible gas c...

Page 3: ...es Use disposable gloves facemasks and eye protection After handling wash hands and other exposed parts If a vacuum is used for cleaning the coals or cleaning after servicing installation it is recomm...

Page 4: ...ob in as far as possible on gas control c Turn knob anti clockwise until a click is heard The knob will stop at the position marked and a flash should be seen at the left hand side of the burner At th...

Page 5: ...normal and adds to the realism of the appliance Some heat discolouration of the firebox sides is also perfectly normal and does not detract from the operation of the fire USE ONLY THE COALS PROVIDED A...

Page 6: ...to coals to have rough sides forward and make sure that they are stable in their positions Place five coals between the first row of coals and the rear matrix as shown Arrange them to look as random a...

Page 7: ...ration of the firebox sides is also perfectly normal and does not detract from the operation of the fire USE ONLY THE PEBBLES PROVIDED NO ADDITIONAL PEBBLES MUST ADDED The Loose pebble set consists of...

Page 8: ...ige colours to give a pleasing layout Place the second row of five large pebbles as shown Again mix the colours Place the top row of four pebbles on top of the rear matrix as shown Place the three sma...

Page 9: ...taken to avoid contact with the refractory lining this is a delicate surface and should not be wiped or rubbed A vacuum cleaner may only be used after all the loose coals have been removed SECTION FI...

Page 10: ...d Assessment Procedure SAP for energy rating of dwellings PACK CONTENTS Components Appliance Owners Instruction Refractory Fuel Bed Wire Fixing Kit Rear Matrix Foam Seal Front Matrix Trim Loose Coals...

Page 11: ...E ITEM AND MUST BE EXCHANGED AS A COMPLETE ASSEMBLY USING ONLY THE ORIGINAL MANUFACTURER S PART A non combustible hearth must be provided to comply with the building regulations or a suitable propriet...

Page 12: ...bris collection Any permanent flue restriction or variable dampers shall be removed or locked fully open The chimney should be swept prior to installation if not new or previously used with a gas appl...

Page 13: ...base of the fireplace opening must be flat to ensure that a good seal is formed between the rear and base of the appliance and the chimney to avoid any reduction of natural draught A non combustible h...

Page 14: ...6891 1988 dealing with enclosed pipes A blind grommet is fitted to the rear of the appliance for the entry of the gas pipe a hole should be cut in the grommet to fit the supply pipe the grommet must b...

Page 15: ...t Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice Check Burner Pressure and General Operation Remove the screw from the pressure test point...

Page 16: ...at room opened and the extractor fan running at maximum setting Should spillage occur seek expert advice Fit the fire front and trim Fit the trim front with the 4 magnets placed on the vertical side f...

Page 17: ...TH SAFETY NOTICE LOCATED ON PAGE 4 OF THIS BOOKLET BEFORE CLEANING OR REPLACING ANY REFRACTORY MATERIAL Refer to coal or pebble layout procedure pages 5 7 before attempting to replace coals or pebbles...

Page 18: ...encer 4 Clean or replace silencer ensuring that it is put back with the open side of the U downwards 5 Re assemble in reverse order Replacement of Oxy Pilot Assembly NOTE If the pilot assembly is repl...

Page 19: ...ound on the label attached to the packaging and on the data badge which is located on the appliance flange top right behind trim Retailer Name ___________________________________________ Address _____...

Page 20: ...LT4934 1 01 08 20...

Page 21: ...LT4934 1 01 08 21...

Page 22: ...LT4934 1 01 08 22...

Page 23: ..._____________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model Enigma II Slimline Serial No Date of Purchase This information can be found on the label attached to...

Page 24: ...mmet Fire Box Grommet Burner Tray Box Assembly Burner Tray Box Assembly Warning Label Fire Guard Warning Label Fire Guard Loose Coals Set 4795 Loose Pebble Set 4792 Rear Matrix Black 4794 Rear Matrix...

Reviews: