MOVE IT LEFT AND RIGHT ALL SMOKE MUST BE DRAWN INTO THE FLUE
POSITION HEAD OF SMOKE MATCH UNDER FIRE OPENING AS SHOWN
CLOSE ALL DOORS AND WINDOWS, LEAVE FIRE BURNING FOR TEN MINUTES
ENIGMA II SLIMLINE
Installation Instructions
SECTION TEN
Checking Operation of Fire
Checking Product Clearance
•
Check
for
satisfactory
clearance
of
combustion
products, close all doors and
windows and leave fire burning
for five minutes.
•
Insert lighted smokes match
10mm into the fire immediately
under the canopy, move match
horizontally along from one side
to the other all the smoke
should be drawn into the flue.
•
If spillage occurs, allow a
further 5 minutes. Should spillage still occur, turn off the fire, remove the restrictor plate (if
fitted) and repeat clearance otherwise seek expert advice.
•
If an extractor fan is situated in the room this test should be repeated with the fan running. If
there is a connected room with an extractor fan, the test should be repeated with all the
doors to that room opened and the extractor fan running at maximum setting. Should
spillage occur seek expert advice.
Fit the fire front and trim
•
Fit the trim front with the 4 magnets placed on the vertical side flanges of the firebox - one
on the top and one at the bottom of each side, and fit the fire front.
•
Offer the decorative trim up squarely and centrally and push into position.
ADVISE CUSTOMER THAT:
The curing effect of heating the fuel bed and other ceramic components will cause an initial
odour. This is due to the starch used in the manufacturing process and is non-toxic. Any debris
should be cleaned from the appliance. A vacuum cleaner can be used but only after all the
loose coals or pebbles have been removed. The appliance should be serviced annually by a
competent person in accordance with these instructions and the appliance checked for spillage
in accordance with the method detailed in these instructions.
Demonstrate the lighting and extinguishing procedures to the user and the removal and refitting
of the decorative trim for cleaning.
If ventilation is fitted for any reason it must be checked regularly to ensure freedom from
obstructions.
Hand these instructions over to the user.