LT4934 (1:01/08)
11
TYPICAL VENTILATION OPENING
ASHTRAY COVER
ENIGMA II SLIMLINE
Installation Instructions
SECTION SEVEN
Regulations and Warnings Cont.
THE FOLLOWING ARE RELEVANT CODES OF PRACTICE AND BRITISH STANDARDS: -
BS 5871
BS 8303
BS 5440 PART 1
BS 1251
BS 6891
BS 6461 PARTS 1 AND 2
BS 715
BS 1289 PART 1
Note:- This appliance must be installed to current versions of the above standards and include
any relevant amendments.
THE BUILDING REGULATIONS ISSUED BY THE DEPARTMENT OF THE ENVIRONMENT.
THE BUILDING STANDARDS (SCOTLAND) (CONSOLIDATED) REGULATIONS ISSUED BY
THE SCOTTISH DEVELOPMENT OFFICE.
PRIOR TO THE INSTALLATION ENSURE THAT THE LOCAL DISTRIBUTION CONDITIONS
(IDENTIFICATION OF TYPE OF GAS AND PRESSURE) AND ADJUSTMENT OF THE
APPLIANCE ARE COMPATIBLE. (G20 @ 20mbar)
WARNINGS
•
This appliance has a naked flame, and with all such fires, it is recommended that a fireguard
should be used for the protection of children, the elderly, or the infirm. Fireguards should
conform to B.S.6539 (1984) (Fireguards for use with solid fuel appliances)
•
This appliance incorporates a safety device in the form of an Oxygen depletion
system. IT MUST NOT BE ADJUSTED OR PUT OUT OF OPERATION! THIS IS A NON
SERVICEABLE ITEM AND MUST BE EXCHANGED AS A COMPLETE ASSEMBLY;
USING ONLY THE ORIGINAL MANUFACTURER'S PART.
•
A non-combustible hearth must be provided to comply with the building regulations, or a
suitable proprietary fire surround with a 100°C minimum rating.
During initial firing, an odour may be evident. This is the starch binder used during the
manufacture of the fibre components of the fire, and there are
no
harmful
effects produced.
Care must be taken to prevent any damage being caused to surrounding soft furnishing or
decoration, e.g. many embossed vinyl wall coverings may become discoloured if placed too
close to the appliance.
IMPORTANT NOTES
A fire front (fret) must be used with this appliance and must conform to the following:
•
It must be made from non-combustible material.
•
Its general construction should enable it to stand firmly
across the full width of the burner.
•
The design of the fire front (fret) must have a removable
ashtray cover (Lower section).
•
The ash tray cover must have cutouts and or holes which
provide ventilation to the underside of the burner.
•
The effective area of ventilation through the ash tray
cover must be greater than 1365mm
2
(2.12 sq. ins.)
This appliance can be used in conjunction with the following chimneys:-
•
Conventional brick or stone chimney,
•
a pre-cast flue (subject to adequate draw) or
•
a metal flue box conforming to BS 715, further details are covered in later text .