FDC ENIGMA II SLIMLINE Owner'S Manual Download Page 11

LT4934 (1:01/08) 

11 

TYPICAL VENTILATION OPENING

ASHTRAY COVER

ENIGMA II SLIMLINE 

Installation Instructions

 

 

SECTION SEVEN 

Regulations and Warnings Cont.

 

 

THE FOLLOWING ARE RELEVANT CODES OF PRACTICE AND BRITISH STANDARDS: - 
BS 5871  

 

 

 

 

 

           BS 8303  

BS 5440 PART 1 

 

 

 

 

 

BS 1251 

BS 6891 

 

 

 

 

 

 

BS 6461 PARTS 1 AND 2  

BS 715 

 

 

 

 

 

 

BS 1289 PART 1  

Note:- This appliance must be installed to current versions of the above standards and include 
any relevant amendments. 
THE BUILDING REGULATIONS ISSUED BY THE DEPARTMENT OF THE ENVIRONMENT. 
THE  BUILDING  STANDARDS  (SCOTLAND)  (CONSOLIDATED)  REGULATIONS  ISSUED  BY 
THE SCOTTISH DEVELOPMENT OFFICE. 
PRIOR TO THE INSTALLATION ENSURE THAT THE LOCAL DISTRIBUTION CONDITIONS 
(IDENTIFICATION OF TYPE OF GAS AND PRESSURE) AND ADJUSTMENT OF THE 
APPLIANCE ARE COMPATIBLE. (G20 @ 20mbar) 

 

WARNINGS 

• 

This appliance has a naked flame, and with all such fires, it is recommended that a fireguard 
should  be  used  for  the  protection  of  children,  the  elderly,  or  the  infirm.  Fireguards  should 
conform to B.S.6539 (1984) (Fireguards for use with solid fuel appliances) 

• 

This  appliance  incorporates  a  safety  device  in  the  form  of  an  Oxygen  depletion 
system. IT  MUST NOT BE  ADJUSTED OR PUT OUT OF OPERATION! THIS IS  A  NON 
SERVICEABLE  ITEM  AND  MUST  BE  EXCHANGED  AS  A  COMPLETE  ASSEMBLY; 
USING ONLY THE ORIGINAL MANUFACTURER'S PART.

 

• 

A  non-combustible  hearth  must  be  provided  to  comply  with  the  building  regulations,  or  a 
suitable proprietary fire surround with a 100°C minimum rating. 

During  initial  firing,  an  odour  may  be  evident.  This  is  the  starch  binder  used  during  the 
manufacture of the fibre components of the fire, and there are 

no

 

harmful

 effects produced. 

Care  must  be  taken  to  prevent  any  damage  being  caused  to  surrounding  soft  furnishing  or 
decoration,  e.g.  many  embossed  vinyl  wall  coverings  may  become  discoloured  if  placed  too 
close to the appliance. 

IMPORTANT NOTES 

A fire front (fret) must be used with this appliance and must conform to the  following: 

• 

It must be made from non-combustible material. 

• 

Its  general  construction  should  enable  it  to  stand  firmly 
across the full width of the burner. 

• 

The design of the fire front (fret) must have a removable 
ashtray cover (Lower section). 

• 

The ash tray cover must have cutouts and or holes which 
provide ventilation to the underside of the burner. 

• 

The  effective  area  of  ventilation  through  the  ash  tray 
cover must be greater than 1365mm

2

 (2.12 sq. ins.) 

 
This appliance can be used in conjunction with the following chimneys:- 

• 

Conventional brick or stone chimney,  

• 

a pre-cast flue (subject to adequate draw) or  

• 

a metal flue box conforming to BS 715, further details are covered in later text . 

Summary of Contents for ENIGMA II SLIMLINE

Page 1: ...LUDES USER INSTALLATION MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in...

Page 2: ...und 13 Clearances at Side of Fire 13 SECTION NINE To Install the Appliance 14 Checking the Flue and Fire Opening 14 Connecting the Gas Supply 14 Concealed gas connection from the rear 14 Visible gas c...

Page 3: ...es Use disposable gloves facemasks and eye protection After handling wash hands and other exposed parts If a vacuum is used for cleaning the coals or cleaning after servicing installation it is recomm...

Page 4: ...ob in as far as possible on gas control c Turn knob anti clockwise until a click is heard The knob will stop at the position marked and a flash should be seen at the left hand side of the burner At th...

Page 5: ...normal and adds to the realism of the appliance Some heat discolouration of the firebox sides is also perfectly normal and does not detract from the operation of the fire USE ONLY THE COALS PROVIDED A...

Page 6: ...to coals to have rough sides forward and make sure that they are stable in their positions Place five coals between the first row of coals and the rear matrix as shown Arrange them to look as random a...

Page 7: ...ration of the firebox sides is also perfectly normal and does not detract from the operation of the fire USE ONLY THE PEBBLES PROVIDED NO ADDITIONAL PEBBLES MUST ADDED The Loose pebble set consists of...

Page 8: ...ige colours to give a pleasing layout Place the second row of five large pebbles as shown Again mix the colours Place the top row of four pebbles on top of the rear matrix as shown Place the three sma...

Page 9: ...taken to avoid contact with the refractory lining this is a delicate surface and should not be wiped or rubbed A vacuum cleaner may only be used after all the loose coals have been removed SECTION FI...

Page 10: ...d Assessment Procedure SAP for energy rating of dwellings PACK CONTENTS Components Appliance Owners Instruction Refractory Fuel Bed Wire Fixing Kit Rear Matrix Foam Seal Front Matrix Trim Loose Coals...

Page 11: ...E ITEM AND MUST BE EXCHANGED AS A COMPLETE ASSEMBLY USING ONLY THE ORIGINAL MANUFACTURER S PART A non combustible hearth must be provided to comply with the building regulations or a suitable propriet...

Page 12: ...bris collection Any permanent flue restriction or variable dampers shall be removed or locked fully open The chimney should be swept prior to installation if not new or previously used with a gas appl...

Page 13: ...base of the fireplace opening must be flat to ensure that a good seal is formed between the rear and base of the appliance and the chimney to avoid any reduction of natural draught A non combustible h...

Page 14: ...6891 1988 dealing with enclosed pipes A blind grommet is fitted to the rear of the appliance for the entry of the gas pipe a hole should be cut in the grommet to fit the supply pipe the grommet must b...

Page 15: ...t Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice Check Burner Pressure and General Operation Remove the screw from the pressure test point...

Page 16: ...at room opened and the extractor fan running at maximum setting Should spillage occur seek expert advice Fit the fire front and trim Fit the trim front with the 4 magnets placed on the vertical side f...

Page 17: ...TH SAFETY NOTICE LOCATED ON PAGE 4 OF THIS BOOKLET BEFORE CLEANING OR REPLACING ANY REFRACTORY MATERIAL Refer to coal or pebble layout procedure pages 5 7 before attempting to replace coals or pebbles...

Page 18: ...encer 4 Clean or replace silencer ensuring that it is put back with the open side of the U downwards 5 Re assemble in reverse order Replacement of Oxy Pilot Assembly NOTE If the pilot assembly is repl...

Page 19: ...ound on the label attached to the packaging and on the data badge which is located on the appliance flange top right behind trim Retailer Name ___________________________________________ Address _____...

Page 20: ...LT4934 1 01 08 20...

Page 21: ...LT4934 1 01 08 21...

Page 22: ...LT4934 1 01 08 22...

Page 23: ..._____________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model Enigma II Slimline Serial No Date of Purchase This information can be found on the label attached to...

Page 24: ...mmet Fire Box Grommet Burner Tray Box Assembly Burner Tray Box Assembly Warning Label Fire Guard Warning Label Fire Guard Loose Coals Set 4795 Loose Pebble Set 4792 Rear Matrix Black 4794 Rear Matrix...

Reviews: