ENIGMA II SLIMLINE
Installation Instructions
SECTION SIX
Appliance Data
Category of appliance:
BII
AS
Category
I
2H
Overall dimensions:
Height 605mm (or 555mm for the Lo version)
Width 505mm
Forward Projection:
75mm, (From fireplace opening including fret.)
Weight:
11kg (Boxed excluding fret) 16.5kg (with fret)
9.5kg (Unboxed excluding fret) 15kg (with fret)
Gas Type:
G20 Natural Gas
Gas Pressure:
20 mbar +/- 1.0mbar
Pressure Test Point Location:
Gas inlet elbow
Gas Input (Gross):
7.0 kW (Maximum) 2.4 kW (Minimum)
Injector:
Marked 460
Gas Connection:
8.0mm O/D, tube.
Data Badge Location:
Behind the decorative trim
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2002 and
the result is 45.28% (50.3% Net). The gross calorific value of the fuel has been used for this
efficiency calculation. GasTec have certified the test data from which it has been calculated.
The efficiency value may be used in the UK Government’s Standard Assessment Procedure
(SAP) for energy rating of dwellings.
PACK CONTENTS
Components Appliance
•
Owners Instruction
Refractory Fuel Bed
•
Wire Fixing Kit
Rear Matrix
•
Foam Seal
Front Matrix
•
Trim
Loose Coals – 20 coals
•
Fret
or Loose Pebbles:- 14 Large,3 Small
SECTION SEVEN
Regulations and Warnings
•
THIS APPLIANCE MUST ONLY BE INSTALLED IN GREAT BRITAIN OR IRELAND.
•
THE APPLIANCE IS SUITABLE FOR USE ON NATURAL GAS ONLY.
•
THE APPLIANCE IS INTENDED FOR DECORATIVE PURPOSES.
•
(GB) NO SPECIAL VENTILATION BRICKS OR VENTS ARE REQUIRED INTO THE ROOM
CONTAINING THE APPLIANCE, PROVIDING NORMAL ADVENTITIOUS ROOM
VENTILATION EXISTS. THE INSTALLER MUST SATISFY THIS POINT BY CARRYING
OUT THE MANDATORY SPILLAGE TEST.
•
(IE) PERMANENT VENTILATION MUST COMPLY WITH THE REGULATIONS
CURRENTLY IN FORCE.
•
IT IS THE LAW THAT ALL GAS APPLIANCES MUST BE INSTALLED BY A COMPETENT
PERSON; I.E. A CORGI REGISTERED INSTALLER, IN ACCORDANCE WITH THE
CURRENT GAS SAFETY (INSTALLATION AND USE) REGULATIONS (AS AMENDED),
ALL RELEVANT PARTS OF THE LOCAL AND NATIONAL BUILDING REGULATIONS AND
ALL RELEVANT RECOMMENDATIONS OF THE FOLLOWING BRITISH STANDARDS.
FAILURE TO DO SO COULD LEAD TO PROSECUTION.