FDC 4, 5, 5W & 8  

Issue 05 10/14

 

Fig 1 - Multi Tool Details 

1. List of Components 

 
Description of Parts 

 

 

Qty 

 
FDC Stove Assembly 

 

 

Door Handle  (screws into knob) 

Multi Tool 

 

 

 

 

Ash Pan  

 

 

 

 

 

Flue Spigot Collar   

 

 

Flue Blanking Plate 

 

 

Spigot Collar fixing screws & nuts 

Blanking plate M6 screws & nuts 

Stove Operating Glove 

 

 

 

 

2. Component Identification and Assembly 

Your stove comes packed in a plywood crate. Carefully remove the straps and lift 

off the upper crate. Remove any plastic packaging, open the door and remove all 

the contents. THE DOOR HANDLE MAY BE PACKED ON TOP OF THE BAFFLE 

PLATE 

– REACH THROUGH THE TOP SPIGOT OPENING TO FIND IT. See List of 

Components section and check contents carefully. 

2.1 To remove the baffle plate, first remove the two stainless steel side firebox liner clips 

by lifting them above the fuel retainer. Remove the two firebox side liners. Now 
remove the firebox rear liner. Handle & store very carefully to one side where they 
will not get broken. 

2.2 Remove the front fuel retainer by lifting up and rotating until it can be lifted through 

the open door of the firebox. 

2.3 Now the baffle plate can be removed by lifting off its supports and bringing out 

through the firebox door opening. 

2.4  Fit the flue spigot collar to the top or rear outlet (as required for the installation) 

using the 4 x M6 set screws and washers supplied. Use 3mm ceramic gasket 
provided or fire cement to seal. 

Fig 2 

– FDC4, FDC5, FDC 5W & FDC8 Stove Assembly and controls 

FDC5 Stove Shown 

 

 

Summary of Contents for 4

Page 1: ...n order to ensure compliance at all times FDC 4 5 5 Wide 8 FREESTANDING STOVE RANGE 4 5 5 8 kW Nominal Outputs With Patented TTi Air System Installation and Operating Instructions Please hand these in...

Page 2: ...lation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 5 4 6 Hearths 6 4 7 Commissioning Handover 6 5 Technical Data Declaration of...

Page 3: ...t of Components section and check contents carefully 2 1 To remove the baffle plate first remove the two stainless steel side firebox liner clips by lifting them above the fuel retainer Remove the two...

Page 4: ...nd BS EN 15287 must be fulfilled The installation is a notifiable building works as defined in the building regulations and that it is a legal requirement under England and Wales Building Regulations...

Page 5: ...possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment 3 1 11 Metal Parts When installing or servicing this...

Page 6: ...tted be used on the FDC 5 5W models ONLY providing that they only burn smokeless fuel or seasoned wood logs with the air limiter fitted in in full accordance with the wood burning instructions An exis...

Page 7: ...nding stoves do not require a constructional hearth beneath them as they do not cause the floor temperature to exceed 100 degrees C Note the optional solid fuel hearth heat shield MUST be fitted when...

Page 8: ...and ensure that the operating instructions and operating tools including gloves for the stove are left with the customer You must be sure to advise the customer on the correct use of the appliance wit...

Page 9: ...5 FDC 5W FDC 8 Domestic Heating Appliances Appliance gross weight packed Kg 54 70 74 81 Harmonized Test Standard EN13240 2001 Amd 2 2004 Quality Constancy Standard ISO9001 Test Report Issue No 6546 2...

Page 10: ...nce exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or ex...

Page 11: ...the pointed part of the multi tool into the knob and lifting up and down or pulling and pushing the knob depending on the model The grate is a strong set of cast iron bars with suitable air slots that...

Page 12: ...ill then control the burn rate of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning After re fuelling open the air wash full for 3 to 5 minutes o...

Page 13: ...open the secondary air wash control fully Then load the firebox with plenty of starting fuel i e paper dry kindling sticks and or firelighters If using Ancit place a layer of ancit into the firebox a...

Page 14: ...the controls are left in this position the fire will eventually go out If you want to revive the fire it is recommended that the primary air controls are open first and then open the secondary air co...

Page 15: ...Open doors and windows to ventilate room and then leave the premises 2 Let the fire out or remove and safely dispose of fuel from the appliance 3 Check for flue chimney blockage and clean if required...

Page 16: ...15 FDC 4 5 5W 8 Issue 05 10 14 8 1 FDC 4 Stove Dimensions...

Page 17: ...16 FDC 4 5 5W 8 Issue 05 10 14 8 2 FDC 5 Stove Dimensions...

Page 18: ...17 FDC 4 5 5W 8 Issue 05 10 14 8 3 FDC 5W Stove Dimensions...

Page 19: ...18 FDC 4 5 5W 8 Issue 05 10 14 8 4 FDC 8 Stove Dimensions...

Page 20: ...ur local Stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact FDC direct 7 Can the doors be left open while burning For safety an...

Reviews: