6.0  Operating Instructions 

 
This appliance is not designed for open operation and therefore should 

not

 be operated 

with the doors open. 
 
This stove is designed to burn wood and smokeless fuels cleanly with high efficiency. 
However, for this product to work properly it must be used correctly. If used correctly this 
stove will burn with the very useful feature of clean glass.  
 
It is 

essential

 that the stove has an adequate air supply for combustion and ventilation. 

DO NOT block any ventilators provided. The primary, secondary and tertiary air inlets 
must be kept clear from obstruction. 

 
Warning! 

This appliance will be very 

hot

 when in operation and due care should be 

taken when operating the controls. A tool and high quality leather gloves are provided to 
assist safe operation. 
 
Do not use an aerosol spray on or near the stove when it is alight. 
 

6.1 The Clean Air Act 1993 and Smoke Control Areas

 

  
Under the Clean Air Act local authorities may declare the whole or part of the district of 
the authority to be a smoke control area. It is an offence to emit smoke from a chimney 
of a building, from a furnace or from any fixed boiler if located in a designated smoke 
control area. It is also an offence to acquire an "unauthorised fuel" for use within a 
smoke control area unless it is used in an "exempt" appliance ("exempted" from the 
controls which generally apply in the smoke control area). 
  
The Secretary of State for Environment, Food and Rural Affairs has powers under the 
Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in 
England. In Scotland and Wales this power rests with Ministers in the devolved 
administrations for those countries. Separate legislation, the Clean Air (Northern Ireland) 
Order 1981, applies in Northern Ireland. Therefore it is a requirement that fuels burnt or 
obtained for use in smoke control areas have been "authorised" in Regulations and that 
appliances used to burn solid fuel in those areas (other than "authorised" fuels) have 
been exempted by an Order made and signed by the Secretary of State or Minister in 
the devolved administrations. 
  
The FDC 5, FDC 5 W & FDC8 have been recommended as suitable for use in smoke 
control areas when burning wood logs. This is conditional upon fitting the supplied 
secondary air control (air wash) limiters and following the wood burning instructions 
precisely. 
  
Further information on the requirements of the Clean Air Act can be found here: 
http://smokecontrol.defra.gov.uk/. Your local authority is responsible for implementing 
the Clean Air Act 1993 including designation and supervision of smoke control areas 
and you can contact them for details of Clean Air Act requirements. 
 

6.2 Air Controls 
Keep air controls clean and free from ash or debris at all times. 
 
Primary Air 

Primary air is controlled via the rotary air controls on the bottom of the door. 

Summary of Contents for 4

Page 1: ...n order to ensure compliance at all times FDC 4 5 5 Wide 8 FREESTANDING STOVE RANGE 4 5 5 8 kW Nominal Outputs With Patented TTi Air System Installation and Operating Instructions Please hand these in...

Page 2: ...lation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 5 4 6 Hearths 6 4 7 Commissioning Handover 6 5 Technical Data Declaration of...

Page 3: ...t of Components section and check contents carefully 2 1 To remove the baffle plate first remove the two stainless steel side firebox liner clips by lifting them above the fuel retainer Remove the two...

Page 4: ...nd BS EN 15287 must be fulfilled The installation is a notifiable building works as defined in the building regulations and that it is a legal requirement under England and Wales Building Regulations...

Page 5: ...possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment 3 1 11 Metal Parts When installing or servicing this...

Page 6: ...tted be used on the FDC 5 5W models ONLY providing that they only burn smokeless fuel or seasoned wood logs with the air limiter fitted in in full accordance with the wood burning instructions An exis...

Page 7: ...nding stoves do not require a constructional hearth beneath them as they do not cause the floor temperature to exceed 100 degrees C Note the optional solid fuel hearth heat shield MUST be fitted when...

Page 8: ...and ensure that the operating instructions and operating tools including gloves for the stove are left with the customer You must be sure to advise the customer on the correct use of the appliance wit...

Page 9: ...5 FDC 5W FDC 8 Domestic Heating Appliances Appliance gross weight packed Kg 54 70 74 81 Harmonized Test Standard EN13240 2001 Amd 2 2004 Quality Constancy Standard ISO9001 Test Report Issue No 6546 2...

Page 10: ...nce exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or ex...

Page 11: ...the pointed part of the multi tool into the knob and lifting up and down or pulling and pushing the knob depending on the model The grate is a strong set of cast iron bars with suitable air slots that...

Page 12: ...ill then control the burn rate of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning After re fuelling open the air wash full for 3 to 5 minutes o...

Page 13: ...open the secondary air wash control fully Then load the firebox with plenty of starting fuel i e paper dry kindling sticks and or firelighters If using Ancit place a layer of ancit into the firebox a...

Page 14: ...the controls are left in this position the fire will eventually go out If you want to revive the fire it is recommended that the primary air controls are open first and then open the secondary air co...

Page 15: ...Open doors and windows to ventilate room and then leave the premises 2 Let the fire out or remove and safely dispose of fuel from the appliance 3 Check for flue chimney blockage and clean if required...

Page 16: ...15 FDC 4 5 5W 8 Issue 05 10 14 8 1 FDC 4 Stove Dimensions...

Page 17: ...16 FDC 4 5 5W 8 Issue 05 10 14 8 2 FDC 5 Stove Dimensions...

Page 18: ...17 FDC 4 5 5W 8 Issue 05 10 14 8 3 FDC 5W Stove Dimensions...

Page 19: ...18 FDC 4 5 5W 8 Issue 05 10 14 8 4 FDC 8 Stove Dimensions...

Page 20: ...ur local Stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact FDC direct 7 Can the doors be left open while burning For safety an...

Reviews: