S-ELE-0029
K61
1
S15:11/=OPT/41.0
5
6
7
8
3
5
2
4
3
Fig. 53: Functional diagrams
1
Relay cross references are used to track signals, which need to be tracked for components with outgoing
contacts. A contact overview with information about the contact types of a relay and their positions in the
circuit diagram is additionally attached to the bottom of each relay coil.
Example: (K61/9.6)
indicates that
the relay coil on page 9 is found in current path 6.
2
Structural symbols
3
Potential cross references serve the purpose of tracking signals, which are transmitted from one func-
tional diagram to another. Potential cross-references may additionally have structural symbols assigned
to them.
Example: → S15:11/=OPT/41.0
is continued to the right to page 41, current path 0.
OPT
stands
for option.
4
Contact overview of relay
5
Current paths are numbered successively from 0 to 9.
The list of components is the first evaluation list that follows the
functional diagrams. This list contains all components used in the
circuit diagram, except terminal strips and plugs.
List of components
Electric systems – Basic principles
BW 900-50
73