8.8.5 Changing the oil in the exciter housing
NOTICE!
Components may get damaged!
–
Use only oil of the permitted specification
Chapter 8.3 ‘List of fuels and lubricants’
.
–
Do not use low-ash engine oils for the exciter
shaft housing.
Protective equipment:
n
Working clothes
n
Protective gloves
1.
Park the machine on level ground.
2.
Park the machine in secured condition
‘Parking the machine in secured condition’ on page 62
3.
Tilt the machine slightly towards the oil drain side and sup-
port it safely.
4.
Unscrew the oil drain plug (1) and collect running out oil.
5.
Stand the machine upright.
6.
Fill in oil up to the bottom edge of the bore.
7.
Screw in the plug (1).
8.
Dispose of oil in an environmentally friendly way.
8.8.6 Replacing the air filter
NOTICE!
Danger of engine damage!
–
Do not start the engine after having removed
the air filter.
Fig. 80
Fig. 81
Maintenance – Annually
BVP 12/50 A
87