Maintenance every year
BOMAG
52
BT 60/4, BT 65/4
6.16 Replacing the starter rope
Fig. 62
Caution
!
Do not mix up the recoil starter fastening
screws by mistake!
l
Unscrew the fastening screws (1), (4) and (6)
(Fig. 62) and take off the recoil starter.
Fig. 63
l
Pull the starter rope with the starter handle out
completely (Fig. 63).
Fig. 64
If the starter rope has been torn or the coil has re-
coiled completely:
l
Before assembling the rope turn the coil (2)
(Fig. 64) 5 revolutions in anti-clockwise direc-
tion and align the rope openings in coil and
housing (5) to each other (A).
Fig. 65
l
Secure the coil (2) (Fig. 65) against winding
up. For this purpose fix coil and housing /5)
with a cable strap (1).
l
Loosen the knots at both ends of the starter
rope and remove the old starter rope.
l
Thread in the new starter rope (3) and fix it with
knots on both ends.
540251
2
5
A
20 mm
0.8 in
20 mm
0.8 in
540250
Go
to
Discount-Equipment.com
to
order
your
parts