![Fayat Group BOMAG BW 900-50 Service Manual Download Page 51](http://html1.mh-extra.com/html/fayat-group/bomag-bw-900-50/bomag-bw-900-50_service-manual_546898051.webp)
6.5
Cleaning the cooling air intake openings
BOMAG
54
008 921 86
6.5
Cleaning the cooling air intake
openings
!
Caution
Dirt in the cooling air intake openings reduces the
cooling effect.
Fig. 8
l
Clean the cooling air intake openings (Fig. 8).
6.6
Check, clean the air filter, re-
place if necessary
!
Caution
A dirty oil filter obstructs the air flow to the carbu-
rettor, which then reduces the engine power.
In a dusty environment you should clean the air
filter every day.
Damaged air filters must be replaced in any case.
It is therefore recommended to keep at least one
air filter in stock.
The air filter must be changed after 500 operating
hours, but at the latest after 2 years.
Incorrectly handled filter cartridges may become
ineffective because of damage (e.g. cracks) and
cause damage to the engine.
Fig. 9
l
Unscrew the air filter cover locking nut (1) (Fig. 9)
and remove the cover (2).
l
Unscrew the wing nut (3).
l
Take out the paper (4) and foam rubber inserts (6).
l
Separate the foasm rubber element from the paper
filter insert.
l
Check both filter elements and replace if damaged.
Fig. 10
l
Clean out the air filter housing with a cloth (Fig. 10).
Go
to
Discount-Equipment.com
to
order
your
parts