Maintenance every 6 months
BOMAG
51
BPR 70/70 D
Maintenance every 6 m onths
5.13 Check the battery condition,
grease the poles
!
Danger
Danger of burning!
When working on the battery do not use open
fire, do not smoke!
Do not let acid come in contact with skin or
clothes!
Wear safety goggles!
Do not lay any tools on the battery!
Fig. 53
l
Loosen the hood fastening screws (1) on both
sides and remove the hood fastening screws
(2) on both sides (Fig. 53).
l
Fold the hood back to open.
Fig. 54
l
Unscrew the battery holder (Fig. 54).
l
Remove the vibration damper mat.
Non-maintenance free batteries:
l
Clean battery and battery compartment.
l
Open plugs and check the acid level.
With control inserts:
l
Check whether the acid level reaches the bot-
tom end of the control inserts.
With transparent battery housing:
l
Check whether the acid level reaches the level
mark on the housing.
Maintenance free batteries:
l
Clean the battery
l
Grease the poles
l
Tighten the terminal clamps
Environment
Dispose of the old batteries environmentally.
!
Danger
Development of gas!
For recharging remove the plugs from the bat-
tery to avoid the accumulation of highly explo-
sive gases.
Go to