Art.824-825

WARNING:

Make sure, too, that the electrical system
to which it is linked has a differential
switch with a 30mA threshold (circuit-
breaker).

Art.825 – FULL-ARM-01/W. Wall version.

TECHNICAL INFORMATION

Power supply

: 12VDC (min. 10VDC, max.

16VDC) or 12VAC (min. 9VAC, max 14VAC),
400mA MAX.
The power supply must be connected to the
internal terminal block for the wall version
FULL-ARM-01/W (Art. 825) or to the external
connector for the table version FULL-ARM-
01/T (Art. 824). If this is carried out for
alternate current (12VAC) it is not necessary
to respect the polarity. For direct current
(12VDC) it is necessary to respect the
polarity: if not the machine will not turn on.
Consumption: 0.07 Amp., with the lamps
turned off, plus 0.08 Amp. for each lamp
turned on. The machine signals, by flashing
the coloured lamps, if the battery needs to be
recharged or if the supply voltage is inferior to
11Volts. This control is very useful in order to
avoid that the excessive discharge can
deteriorate the battery.
The version FULL-ARM-01/T (Art. 824) is
supplied with a feeding cable equipped with
the connector.

To the DATA-LINE outlets placed behind, you
can connect 2 LIGHTS REPEATERS or 2
panel repeaters PANEL 02 (Art. 835).

Unscrew the 7 screws at the back and
remove the plastic back panel. Carry out the
connection of the weapons and of the power
supply using the terminal block at the top
following the internal scheme. Replace the
back panel making the cables pass through
its special slit at the bottom on the left.
Rescrew the back screws. Connect the
eventual LIGHTS REPEATERS by inserting
the telephone type connectors in the DATA-
LINE sockets. Fix the FULL-ARM-01 on the
wall using the two frontal holes and the two
screws you are supplied with.

Unscrew the back

screws and remove the plastic back panel.
Disconnect the eventual connections to the
terminal block. Insert the connector of the flat
cable coming out of the TABLE ADAPTER to
the proper socket situated between the
terminal block and the DATA-LINE sockets.
Replace the back panel making the flat cable
pass through the lower side. Rest the TABLE
ADAPTER ontop and in the middle and fix it
using the three long screws you are equipped
with (one superior screw and two lower
screws). Rescrew the 4 remaining screws to
the back panel.

The table version is supplied with a metal
support equipped, at the rear, with sockets for
the connection of the weapons and for the
power supply.

it is necessary to remove the

plastic back panel and connect the two wires
of the contact of the chronometer to the
terminal block, as indicated internally by the
writing CHRON. Moreover it is necessary to
move the jumper, positioned near the terminal
block, from the position A to the position B.

if the power supply is carried

out with a transformer or feeder connected
to the electrical supply, you must make
sure that it has a double insulation and
protected against short circuits.

Art.824 – FULL-ARM-01/T. Table version.

INSTALLATION

Eventual fixing of the table support TABLE
ADAPTER (Art. 826).

F o r t h e c o n n e c t i o n o f a n e x t e r n a l
chronometer

ENGLISH

OPERATING

TECHNICAL INFORMATION

INSTALLATION

ON-OFF

VOLUME SON haut/bas

FLEUR.

ÉPÉE

SABRE

VERS. PROGR

TEMPS RÉARM

RÉARM

RÉARM

ON-OFF

VOLUME SON haut/bas

ON-OFF

Art.894

Art.894-A:
Art.894-B:
Art.894-C:

A r t . 8 9 4 - A a n d

A r t . 8 9 4 - B

L I G H T S

REPEATER 220V and 115V.

Art.894-C – LIGHTS REPEATER 12VAC.

All versions

key. Turns on and off the FULL-

ARM-01. In the OFF position FULL-ARM-01
has a minimum consumption of 0.05A and
therefore, if fed with a battery, it is convenient
to disconnect it when it is not used.

key. Press down to

select one of the two sound levels.

key. Selects the

weapon being used.

key. It is active only for the

sabre for which it is possible to select 2
programmes:

if there is a whip-over the

touch is not valid (as for the F.I.E. rules).

the touch is valid also if there

is a whip-over.

key. Set the mode for

automatic or manual rearmament. In the
automatic modality it is possible to select
times of 1, 3, 5 sec.

key. For the rearmament.

W h i l e p r e s s i n g t h e

key press the

key. In this

way you will enter the test phase.
At this point, pressing repeatedly the

key, all the lamps

will turn on in succession.
Moreover, short circuiting among themselves,
all the 7 sockets for the weapons, a
continuous sound will indicate the correct
functioning of the control circuits for the
weapons.
To exit the test: re-press the

key.

220VAC, 6VA MAX;
115VAC, 6VA MAX;
12VAC, 400 mA MAX.

These versions

are supplied with a feeding cable and plug.
Insert the telephone type plug in the DATA-
LINE socket. Fix the LIGHTS REPEATER on
the wall using the two frontal holes and the
two screws you are supplied with.

Unscrew the rear screws and remove the
plastic back panel. Carry out the connection
of the power supply using the internal
terminal block. Replace the back panel
making sure the feeding cable passes
through its special slit at the bottom on the
left. Rescrew the rear screws. Insert the
telephone type plug in the DATA-LINE socket.
Fix the LIGHTS REPEATER on the wall using
the two frontal holes and the two screws you
are supplied with.

of the LIGHTS REPEATER are

equipped with a telephone type cable 30mt
long for the connection of the DATA-LINE to
the FULL-ARM-01.
This cable can be easily extended up to
100mt by purchasing the special extensions.
On the other hand, you can cut the cable and
extend it with only two wires and connecting
one wire to the two central wires and the
second wire to the two lateral wires (the cable
has four wires).
A luminous red indicator situated near the
DATA-LINE socket indicates the situation of
the connection with FULL-ARM-01.

the connection is correct.

t h e c o n n e c t i o n i s

imperfect or the FULL-ARM-01 is off.

lack of power supply to the

LIGHTS REPEATER or it has broken-down.

1)

2)

Power supply according to the versions.

Indicator on:

Indicator off:

Indicator always on:
F l a s h i n g i n d i c a t o r :

Indicator off:

T E S T F U N C T I O N .

LIGHTS REPEATER

FULL-ARM-01

Summary of Contents for FULL-ARM-01

Page 1: ...NLEITUNGEN FRANÇAIS INSTRUCTIONS TECHNIQUES ESPAÑOL INSTRUCCIONES TÉCNICAS Art 824 FULL ARM 01 T Art 825 FULL ARM 01 W Art 894 LIGHTS REPEATER 12V AC 12V AC FULL ARM 01 LIGHTS REPEATER Piste Pedana DATA LINE 12V AC 12V AC FULL ARM 01 DATA LINE DATA LINE 12V AC LIGHTS REPEATER LIGHTS REPEATER Examples of connections Piste Pedana ...

Page 2: ...one B INSTALLAZIONE Eventuale fissaggio del supporto da tavo lo TABLE ADAPTER Art 826 Art 824 FULL ARM 01 T Versione da ta volo Per il collegamento di un cronometro esterno ITALIANO FUNZIONAMENTO INFORMAZIONI TECNICHE INSTALLAZIONE Tasto Accende e spegne il FULL ARM 01 Nello stato di OFF il FULL ARM 01 ha un consumo minimo di 0 05A e quindi se viene alimentato a batteria è opportuno scol legarlo q...

Page 3: ...nsulation and protected against short circuits Art 824 FULL ARM 01 T Table version INSTALLATION Eventual fixing of the table support TABLE ADAPTER Art 826 For the connection of an external chronometer ENGLISH OPERATING TECHNICAL INFORMATION INSTALLATION ON OFF VOLUME SON haut bas FLEUR ÉPÉE SABRE VERS PROGR TEMPS RÉARM RÉARM RÉARM ON OFF VOLUME SON haut bas ON OFF Art 894 Art 894 A Art 894 B Art 8...

Page 4: ... 825 FULL ARM 01 W Wandausführung Art 824 FULL ARM 01 T Tischausführung INSTALLATION Eventuelle Befestigung der Tischhalterung TABLE ADAPTER Art 826 F ü r d e n A n s c h l u ß e i n e r ä u ß e r e n Kontrolluhr DEUTSCH FUNKTIONSABLAUF TECHNISCHE INFORMATIONEN INSTALLATION Taste Stellt den FULL ARM 01 an und ab Wenn der FULL ARM 01 auf OFF steht hat er einen Minimalverbrauch von 0 05 Amp Wenn das...

Page 5: ...t 824 FULL ARM 01 T Version de table INSTALLATION Eventuelle fixation du support de table TABLE ADAPTER Art 826 Pour le branchement d un chronomètre ex térieur FRANÇAIS FONCTIONNEMENT DONNÉES TECHNIQUES INSTALLATION Touche Elle sert à allumer ou étein dre le FULL ARM 01 En position OFF la con sommation du FULL ARM 01 est de 0 05A mi nimum Par conséquent en cas d alimentation par batterie il est co...

Page 6: ...1 W Versión de pa red Art 824 FULL ARM 01 T Versión de sobre mesa INSTALACIÓN Eventual fijación del soporte de sobremesa TABLE ADAPTER Art 826 Para el conexionado de un cronómetro exte rior ESPAÑOL FUNCIONAMIENTO INFORMACIONES TÉCNICAS INSTALACIÓN Tecla Enciende y apaga el FULL ARM 01 En el estado de OFF el FULL ARM 01 tiene un consumo mínimo de 0 05A por consiguiente si se alimenta a batería es p...

Reviews: