1st edition, 9.04.2024
7000.05073, 1st edition, 9.04.2024
7000.05073
Safety
9
2.2.1
Dangers in the event of damages and changes
Damage to the Motion Control Systems (MCS) can impair its functions. A damaged MCS can
unexpectedly start, stop or jam. This can result in damage to other components and materi
-
als.
Do
not
start up a drive system with a defective or damaged MCS.
Appropriately mark a defective or damaged MCS.
Do
not
replace defective or damaged components of the MCS.
Make no changes (modifications, repairs) to the MCS.
Have loose or defective connections immediately replaced by an electrician.
After replacing a defective or damaged MCS, test and document the correct function.
2.2.2
Correct installation and commissioning
Errors during the installation and commissioning of the MCS could impair its function. An
incorrectly installed MCS can unexpectedly start, stop or jam. This can result in damage to
other components and materials.
Follow the instructions for installation and commissioning given in these installation
instructions exactly.
Only have work on electrical operating equipment performed by an electrician.
During all work on the electrical equipment, observe the 5 safety rules:
a) Disconnect from power
b) Secure against being switched on again
c) Check that no voltage is present
d) Ground and short-circuit
e) Cover or block-off adjacent parts that are under voltage
Electrostatic discharges can damage the electronics.
Store and transport the MCS in suitable ESD packaging.
Handle the MCS in compliance with the ESD handling regulations (e.g. wear an ESD
wristband, ground surrounding components).
During installation, ensure that components in the surroundings cannot be electrostati
-
cally discharged.
Soiling, foreign bodies, humidity and mechanical influences can damage the electronics.
Keep foreign objects away from the electronics.
Install the MCS in a housing that protects it from mechanical influences and is adapted
to the ambient conditions (protection class determination).
Installation and connection work whilst supply voltage is applied at the device can dam
-
age the electronics.
Do
not
insert or withdraw connectors whilst supply voltage is applied at the MCS.
Prior to all aspects of installation and connection work on the MCS, switch off the
power supply.
Incorrect connection of the pins can damage the electronic components.
Connect the wires as shown in the connection assignment.