1st edition, 9.04.2024
7000.05073, 1st edition, 9.04.2024
7000.05073
Installation
30
4.3.3.2
Establishing shield connection with cable lug
A shield connection with cable lug should be avoided whenever possible. If it is necessary,
however, the connection should be established as follows.
Fig. 21: Shield connection with cable lug
1. Scrape the surface around the hole to remove as much of the oxide layer as possible.
2. Guide screw with washers through the cable lug.
3. Place lock washer on the screw.
Depending on the screw length, also position the lock washer against the roughened
surface.
4. Fix screw with nut on the bottom side or screw into the thread.
1
Screw
2
Nut
3
Spring washer
4
Washer
5
Lock washer
6
Wall
7
Wire eyelet
8
Protective conductor
3
2
1
4
6
5
4
7
8
1