Thank you for purchasing FATEK HMI. Before installing or operating the unit, please 

read this installation guide carefully to ensure correct use. 

 

1. Safety Precautions 

(Read these precautions before use.)

 

1.1 General 

z

  Unpack and check the delivery for transportation damage. If any damage or 

deformation is found, please notify the supplier. 

z

  The supplier is not responsible for the disassembled, altered or modified 

device. 

z

  Never allow fluid or any conductive particles to enter into the HMI. 

Otherwise, it may damage the HMI, cause fire or malfunction. 

z

  Only qualified personnel may install the HMI, perform maintenance and 

inspection. 

z

  The liquid crystal inside the LCD panel is a hazardous substance. If the 

panel is damaged, avoid contact with the leaked liquid crystal. If the liquid

crystal spills on clothing or skin, use soap and wash off thoroughly. In case 

of eye contact the liquid, hold the eye open, flush with plenty water and get 

medical attention as soon as possible. 

z

  Do not touch any terminals while the power is on. Otherwise, it may cause 

injury due to electrical shock. 

z

  Disconnect the power supply before installing the HMI, do wiring operation, 

perform maintenance or inspection. Otherwise, it may cause damage or

electrical shock. 

1.2 Installation 

z

  The installation may be carried out by

 

qualified

 

personnel

 

only.

 

z

  Install the HMI according to the installation procedures. 

z

  Check the power source voltage is within the specified range and the

polarity is correct before connecting the HMI

.

 

z

  Keep signal and power supply cables away from high-voltage, large-current 

carrying cables. 

P5102S/N/N1 HMI Installation Guide

 

R

Summary of Contents for P5102S

Page 1: ...damaged avoid contact with the leaked liquid crystal If the liquid crystal spills on clothing or skin use soap and wash off thoroughly In case of eye contact the liquid hold the eye open flush with plenty water and get medical attention as soon as possible z Do not touch any terminals while the power is on Otherwise it may cause injury due to electrical shock z Disconnect the power supply before i...

Page 2: ... contact our sales department z Do not use the output signal of the device as any safety function or system emergency stop It may result in personal injury or equipment damage if a malfunction of the touch occurs 1 4 Maintenance and Service z The agreed guarantee applies z Only qualified personnel should make repairs and perform maintenance z Disconnect the device from the power supply before carr...

Page 3: ...Switch HB1 PLC Screw Hole Power Connector COM3 COM4 Pluggable Terminal Block Ethernet RJ45 Connector for N N1 model Mini USB Connector USB Connector COM1 DB 9 Male Connector Micro SD Card Slot for N1 model Audio Phone Jack for N1 model W 271 5 mm H 213 5 mm D 44 6 mm 1 2 3 4 5 6 7 8 9 10 11 12 13 W H D 3 ...

Page 4: ...ment type Permanently connected Fixed I O Port Serial 1 Connector D Sub 9 Pin COM1 RS 232 TXD RXD RTS CTS Serial 2 Connector Pluggable Terminal Block COM3 RS 422 485 Isolation COM4 RS 485 Isolation LAN 10M 100M 10M 100M USB USB2 0 Type A Host x1 USB2 0 Type mini B Device x1 Micro SD Yes Audio Yes PLC Extension HB1 main units B1 extension modules Termination Switch Yes For RS 422 485 Power Power In...

Page 5: ...nstallation Procedures z Push the HMI into the cutout until the waterproof ring contacts the plate z Insert a hook into each mounting hole on the HMI and then tighten the screws evenly with a moderate torque z Failure to tighten the screws may cause the HMI to fall malfunction or short circuit Excessive tightening may cause deformation The necessary torque is about 0 16N m 5 ...

Page 6: ...on resistor switch To enable or disable the termination resistor please follow the configuration shown in the table below The termination switch is for COM3 RS 422 RS 485 and COM4 RS 485 z Configuration of Termination Resistor Switch Termination Resistor No COM3 RS 422 COM3 RS 485 COM4 RS 485 Enable Disable Enable Disable Enable Disable 1 ON OFF OFF OFF OFF OFF 2 ON OFF OFF OFF OFF OFF 3 ON OFF ON...

Page 7: ...S 232 1 NC 1 2 RX 3 TX 4 NC 5 GND 6 NC 7 RTS 8 CTS 9 NC 1 NC No Connection Pluggable Terminal Block PIN COM3 RS 422 COM3 RS 485 COM4 RS 485 1 NC NC DATA 2 NC NC DATA 3 ISO_GND ISO_GND ISO_GND 4 RX NC NC 5 RX NC NC 6 TX DATA NC 7 TX DATA NC 1 2 3 4 5 6 7 7 ...

Page 8: ...and saving space using FATEK HB1 main units B1 extension modules is recommended z The rubber cover of the PLC connector can be taken off and placed into the termination switch slot 8 R Pobrano z https panele hmi pl panel hmi 10 2 p5102s fatek ...

Reviews: