Functional Description
CPC805
C P C 8 0 5 U s e r M a n u a l
35
© 2 0 1 2 F a s t w e l v . 0 0 1 a E P r e
2.1.13
Soft Power and Reset Connectors
2-pin connectors SoftPower and Reset (XP8 and XP9) are located on the top side of the module.
They are used for connection of remote buttons without closed (depressed) state latching.
A button connected to XP8 pins allows to switch between several power states. Pressed once in
S5 (Soft-off) mode, it switches the module into S0 (Full-on) mode. Pressed once in S0 (Full-on)
mode, it switches the system into S1, S3 or S5 mode depending on setup settings. Retention of
this button in pressed position for more than 4 seconds in S0 (Full-on) mode switches the system
into S5 (Soft-off) mode.
Depressing the button connected to XP9 pins initiates system Reset and restart of the module.
(TBA)
2.1.14 Counterpart
Connectors
The user can make custom cables for connection to the CPC805 onboard connectors using the
information on the counterpart connectors below:
Table 2-11:
Recommended Counterparts for Onboard Connectors
Onboard Connector
Counterpart
XP17
IDC2-26
XP20, XP21
MU-5F
XP22
BLS-7
XP24, XP25, XP26
MU-3F
XP6
MF-2F
XP5
MF-10F
XP3