![Fastwel CPB902 User Manual Download Page 80](http://html.mh-extra.com/html/fastwel/cpb902/cpb902_user-manual_546458080.webp)
General Software® BIOS
CPB902
C P B 9 0 2 U s e r M a n u a l
78
© 2 0 0 8 F a s t w e l v . 1 . 5 b E
5.6
PnP Configuration
This BIOS Setup section provides access to Plug-and-Play related IRQ and DMA assignments.
The menu screen is shown in the figure below.
Figure 5.5:
Plug-n-Play Configuration Menu Screen Image
╔══════════════════════════════════════════════════════════════════════════════╗
║
System BIOS Setup - Plug-n-Play Configuration
║
║
(C) 2005 General Software, Inc. All rights reserved
║
╠═══════════════════════════════════════╤══════════════════════════════════════╣
║
Enable PnP Support :>Enabled
│
Enable PnP O/S : Enabled
║
║
│
║
║
Assign IRQ0 to PnP : Disabled
│
Assign IRQ8 to PnP : Disabled
║
║
Assign IRQ1 to PnP : Enabled
│
Assign IRQ9 to PnP : Disabled
║
║
Assign IRQ2 to PnP : Enabled
│
Assign IRQ10 to PnP : Disabled
║
║
Assign IRQ3 to PnP : Enabled
│
Assign IRQ11 to PnP : Enabled
║
║
Assign IRQ4 to PnP : Disabled
│
Assign IRQ12 to PnP : Enabled
║
║
Assign IRQ5 to PnP : Enabled
│
Assign IRQ13 to PnP : Enabled
║
║
Assign IRQ6 to PnP : Disabled
│
Assign IRQ14 to PnP : Enabled
║
║
Assign IRQ7 to PnP : Disabled
│
Assign IRQ15 to PnP : Enabled
║
║
│
║
║
Assign DMA0 to PnP : Disabled
│
Assign DMA4 to PnP : Disabled
║
║
Assign DMA1 to PnP : Disabled
│
Assign DMA5 to PnP : Enabled
║
║
Assign DMA2 to PnP : Disabled
│
Assign DMA6 to PnP : Enabled
║
║
Assign DMA3 to PnP : Enabled
│
Assign DMA7 to PnP : Disabled
║
║
│
║
║
│
║
╠═══════════════════════════════════════╧══════════════════════════════════════╣
║
↑/↓/→/←
/<CR>/<Tab> to select or <PgUp>/<PgDn>/+/- to modify
║
║
<Esc> to return to main menu
║
╚══════════════════════════════════════════════════════════════════════════════╝
All items allow to choose between the two options – “Enabled” or “Disabled”. Use arrow keys,
<Tab> key and <Enter> to move between items and for selection. <PgUp>, <PgDn>, <+> or <->
are used to change the selected parameter, <Esc> – to return to the Main Menu.