- 29 -
Appendix A: Function parameter table
“R”
:
Indicates that the parameter displays the actual test record value and cannot be changed;
“W”
:
Indicates that the setting value of the parameter can be changed when the power controller is
in shutdown and running state;
“T”
:
Indicates that the setting value of the parameter cannot be changed when the power controller
is in the running state;
“X”
:
Indicates that the parameter is a "manufacturer parameter", which is only set by the
manufacturer and cannot be operated by the user;
Function
code
Name
Range
Factory
value
Property
Description
0
:
Basic information
0.01
Running state
0
、
1
-
R
0:Stop
1:RUN
0.02
A/M state
0
、
1
-
R
0: (1.11) M input
1: (1.10) A input
0.03
Uin
0.0
~
3276.7
-
R
Input voltage
0.04
Uout
0.0
~
3276.7
-
R
Output voltage
0.05
Iout
0.0
~
3276.7
-
R
Output Current
0.06
Pout
0.00
~
327.67
-
R
0.07
Power factor
0.00
~
1.00
-
R
0.08
Start signal
0
、
1
-
R
Terminal RUN state
0.09
IN1 input (%)
0
.
00
~
100.00%
-
R
Terminal IN1
4~20mA input
0.10
IN2 input (%)
0
.
00
~
100.00%
-
R
Terminal IN2
0~5V / 0~10V
0.11
Pannel input (%)
0
.
00
~
100.00%
-
R
Expansion
Pannel input
FTM1 TYPE SCR power controller