www.fastech.co.kr
39
Other Operation Functions
8-2.Jog Operation Example
It starts speed control operation using a parameter condition by Jog+, Jog- signal input.
【Parameter Setting】
No.
Parameter Name
Setting Value
Unit
6
Jog Speed
1500
[pps]
7
Jog Start Speed
100
[pps]
8
Jog Acc Dec Time
200
[msec]
Also, when any value except 0 is set to the ‘Jog Start Speed’ parameter, the relation between jog
command and in-position is indicating as below diagram.
Jog+ command
Jog- command