
-61-
7.3 Connecting
7.3.1 Connection the power supply
Power cable connects to CN1.
* Power cable not included. (Only connector included)
Connector : CN1
Manufacturer : STELVIO
Part number : CPF5.08-05P
Attension
•
Input the power after check rated voltage of drive.
•
If the voltage exceeds the rated range, the drive will be broken.
Input Power
Connect Method
Single-Phase 100-120V
Single-Phase 200-240V
Wire connect to L1 and L2 terminals
Three-Phase 200-240V
Connect the R, S,and T phase lines to the L1, L2 and L3 terminals
each.
Single-Phase 100-120V Three-Phase 200-240V
Single-Phase 200-240V
•
Connecting of lead wire
- Lead wire Size : AWG18 ~ 14(
0.75 ~ 2.0 𝑚𝑚
2
)
- Length of lead wire stripping : 8mm
- Conductor material : Only use copper wire.
Summary of Contents for Ezi-Speed ST
Page 1: ......
Page 9: ...9 2 Characteristics 2 1 Part number...
Page 18: ...18 3 2 Dimensions 30W 60W 120W Drive 200W 400W Drive...
Page 21: ...21 4 2 Dimensions ESM 60 S 30 ESM 80 S 60 ESM 90 S 120...
Page 22: ...22 ESM 104 S 200 ESM 104 S 400...
Page 23: ...23 4 3 Characteristics of motor torque 30W 60W 120W...
Page 24: ...24 200W 400W...
Page 29: ...29...
Page 41: ...41 6 2 External wiring diagram Input Voltage 110V Drive...
Page 42: ...42 Input Voltage 220V Drive...
Page 80: ...80 8 2 Setting and 7 segments display 1 Monitor mode...
Page 81: ...81 2 Input Output setting mode...
Page 82: ...82 3 Parameter setting mode 1page...
Page 83: ...83 3 Parameter setting mode 2page...
Page 84: ...84 3 Parameter setting mode 3page...
Page 85: ...85 3 Parameter setting mode 4page...
Page 86: ...86 4 NVM saving mode...