background image

Fasep 2000 srl

Rev. 1.6

Videotronic V548.G4: User’s Manual

15 April 2019

2

WARNING

.This document contains information which is the property of FASEP 2000 rl and all rights are reserved. This manual shall not be
photocopied or reproduced in any way without the prior written consent of FASEP 2000 srl.

.FASEP 2000 srl reserves the right to revise products firmware, software or documentation without obligation to notify any person
or organization. The information contained in this document is subject to change without warning.

.Prior of the installation of the unit described in this manual, user should read this manual carefully to be instructed properly on
installation, use and maintenance of the unit.

.

Failing to read this manual and operate accordingly may cause damage to the user or the unit

.

.FASEP 2000 srl shall not be responsible for inconvenience, breakdown, accidents due to uncomplete knowledge of this manual
or uncomplete application of raccomendations described in this manual.

.FASP 2000 srl shall not be responsible for inconvenience, breakdown, accidents due to unauthorized modifications of the unit, use
of non-original or unauthorized accessories (see Accessories listing in this manual for a list of original accessories available for this
model).

.

FASEP 2000 srl shall not be responsible for any inconvenience, breakdown, accidents caused directly or indirectly by not

qualified service. Service to any parts by not qualified persons will void warranty and will void any right of the owner of
the unit.

SYMBOLS AND CONVENTIONS

To speed the retrieval of main information and make easy to understand the instructions, this manual uses the following typing
conventions:

<NAME OF THE PUSH BUTTON>

Used to indicate name of push-buttons on the control panel.

DISPLAY

Used to indicate text or number visible on the displays on the control panel.

ADVICES

Contain useful advices or solutions,  evidence d with respect to the rest of the text.

NOTE

Notes contain important information, evidenced to the rest of the text.

WARNING

Warning messages appears corresponding to procedures that, if not properly observed,

may lead to loose of data or cause damage to the unit.

!

CAUTION

Caution messages appears corresponding to procedures that, if not properly observed,
may cause injuries to the user.

Summary of Contents for VIDEOTRONIC V548.G4

Page 1: ...nual 15 April 2019 For any information please contact www fasep it e mail support fasep it FASEP 2000 srl Via Faentina 96 Ronta 50032 Borgo San Lorenzo Fi Italy Tel 39 055 840 3126 Fax 39 055 840 3354...

Page 2: ...ence breakdown accidents due to unauthorized modifications of the unit use of non original or unauthorized accessories see Accessories listing in this manual for a list of original accessories availab...

Page 3: ...cer 9 4 2 How to control the calibration of wheel balancer and position weight 10 5 Calibration ALU SE 11 6 Calibration SME 12 7 MEASUREMENT AND CORRECTION OF UNBALANCE 13 7 1 Placing the wheel rim on...

Page 4: ...he unit and must be purchased separately This unit is designed for indoor use only see Environmental Data appendix for reference CAUTION This unit is designed to spin vehicle wheels only within the ra...

Page 5: ...ed at the installation site This switch should provide on off control and overload protection for your wheel balancer only The switchbox should be fused with time delay fuse s in accordance with the p...

Page 6: ...April 2019 6 3 USE OF CONTROL PANEL 3 1 Meaning of the icons on the screen Select balancing mode APS Function Calibration Delete last character in input activation code Change selection Set default va...

Page 7: ...revious page Fine resolution Access to Information center Access to page measures Laser calibration Put in the rod laser in rest position Start laser Extract fully rod laser Manul input measures Set D...

Page 8: ...are Reset partial statistics Reset variation in page Sensor Save Set measures Go to setup men Skip current operation Split function Stop turning wheel Key up View men and selection UP DOWN Automatic f...

Page 9: ...c indicated point of unbalance constantly wrong d more than 2 spins required to balance wheels repeatedly Switch on the wheel balancer Select SET UP CALIBRATION SET OK CALIBRATION SET OK Spin with no...

Page 10: ...t a wheel on the shaft and press START Fig 46 Put the calibration weight Fig 47 and press SET OK Close the wheel guard or press START At the end of the spin 160 0 will show on the video tolerance allo...

Page 11: ...balancer MAIN MENU MENU RESET CALIB ALU SE CALIBRATION SET OK fig 49 Put the rod on rest position fig 49 and press SET OK Put the rod on the flange fig 50 and press SET OK Select width of wheel Put th...

Page 12: ...April 2019 12 6 Calibration SME Switch on the wheel balancer MAIN MENU MENU RESET CALIB SME CALIBRATION SET OK fig 52 Put the rod on rest position fig 52 and press SET OK Put the rod fig 53 and press...

Page 13: ...centering and tightening of the wheel on the flanges is of basic importance for correct balancing Good results depend on proper performance of these procedures To accurately clean up the superficial...

Page 14: ...the distance IN1 Insert the distance IN2 7 4 Detecting and correcting umbalance 7 4 1 After setting wheel dimensions press START or close the safety cover to spin the wheel and start the measurement...

Page 15: ...ach the application position of the weight Apply the weight fig 63 Repeat the procedure for the other side 7 6 How to use SPLIT Program After the measurement spin Press SPLIT to select the program Tur...

Page 16: ...er s Manual 15 April 2019 16 8 SPECIAL FUNCTIONS 8 1 Language selection 8 1 1 MAIN MENU SET UP USER SET UP LANGUAGE SET OK 8 1 2 Select the language and press SET OK 8 2 Setup 8 2 1 MAIN MENU SET UP U...

Page 17: ...quirement 400W Speed Balancing 98RPM Measuring time 4 15 s Accuracy 1grammo 1 28 once Wheel Dimensions Diameter Rim diameter 8 200 mm 26 650 mm Rim Width with wheel guard max 16 415mm Wheel Weight max...

Page 18: ...directly by unauthorized service Service to any parts by unauthorized engineers will void warranty and will any right of the owner of the unit NOTE As this unit runs at speed below 100rpm a safety cov...

Page 19: ...l number not inserted ERR 13 Reserved ERR 14 Incorrect password ERR 15 E prom error ERR 16 Calibration memory error ERR 17 Rod in incorrect position ERR 18 Excessive weight detected ERR 19 Hand spin i...

Reviews: