9.2
Fixtures contained in the packing
The packing case contains also the fixtures box.
Check that all the parts listed are there.
Code
Description
N.
14620010
Clamp
1
B5119000
Long lever “A”
1
10.0 ELECTRICAL CONNECTIONS
EVEN THE TINIEST PROCEDU-
RE OF AN ELECTRICAL NATURE
MUST BE CARRIED OUT BY PRO-
FESSIONALLY QUALIFIED STAFF.
BEFORE CONNECTING THE MA-
CHINE MAKE SURE THAT:
• THE MAIN POWER RATING COR
-
RESPONDS TO THE MACHINE
RATING AS SHOWN ON THE
MACHINE PLATE;
• ALL MAIN POWER COMPO
-
NENTS ARE IN GOOD CONDI-
TION;
• THE ELECTRICAL SYSTEM
IS PROPERLY GROUNDED
(GROUND WIRE MUST BE THE
SAME CROSS-SECTION AREA
AS THE LARGEST POWER SUP-
PLY CABLES OR GREATER);
• MAKE SURE THAT THE ELEC
-
TRICAL SYSTEM FEATURES A
CUTOUT WITH DIFFERENTIAL
PROTECTION SET AT 30 mA.
The machine is supplied with
5
m of free cable. A plug
corresponding to the following requirements must be
connected to the cable:
• Conformity to Norm
IEC 309
• 230/400 Volt – 16A
• 3P + Ground
• IP 44
7522-M001-14_P
GG40256.11SL - GG40256.11ST - GG40256.15
GG40256T.15 - GG40256A.15 - GG40256D.15
GG40256TD.15 - GG40256.15SL - GG60360.15
GG60360T.15 - GG60360A.15 - GG60360D.15 - GG60360TD.15
Only for GG40256D.15, GG40256TD.15,
GG40256.11SL (VARGNAV43AD), GG40256.15SL
(model with inverter version) (VARGNAV43AD)
GG60360D.15 and GG60360TD.15 versions
• Conformity to Norm
IEC 309
• 230/400 Volt – 32A
• 3P + N + Ground
• IP 44
On delivery, the machine is pre-set to operate at a
voltage of 400 V.
For any other type of power supply, ask the manufac-
turer at the time of purchase: a machine functioning
under the required voltage conditions will be prepared.
FIT A TYPE-APPROVED (AS RE-
PORTED BEFORE) PLUG TO THE
MACHINE CABLE (THE GROUND
WIRE IS YELLOW/GREEN AND
MUST NEVER BE CONNECTED TO
ONE OF THE PHASE LEADS).
MAKE SURE THAT THE ELEC-
TRICAL SYSTEM IS COMPATIBLE
WITH THE RATED POWER AB-
SORPTION SPECIFIED IN THIS
MANUAL AND APT TO ENSURE
THAT VOLTAGE DROP UNDER
FULL LOAD WILL NOT EXCEED
4% OF RATED VOLTAGE (10%
UPON START-UP).
IN CASE OF A CHANCE SUPPLY
FAILURE, AND/OR BEFORE ANY
POWER SUPPLY CONNECTIONS,
MOVE THE PEDALS TO THE NEU-
TRAL POSITION.
10.1 Oil check on oil-pressure power unit
THE OIL-PRESSURE POWER
UNIT IS DELIVERED WITHOUT
HYDRAULIC OIL, THEREFORE
MAKE SURE THE TANK PROVIDED
IS FILLED WITH OIL WITH VISCO-
SITY DEGREE APPROPRIATE TO
THE AVERAGE TEMPERATURES
IN THE INSTALLATION COUNTRY
AND IN PARTICULAR:
- VISCOSITY 32 (FOR COUNTRIES
WITH ROOM TEMPERATURE
FROM 0 TO 30 DEGREES);
- VISCOSITY 46 (FOR COUNTRIES
WITH ROOM TEMPERATURE
ABOVE 30 DEGREES).