background image

Fasep 2000 srl

Rev. 1.3

Balatron B110, B210: User

’s Manual

15 July 2013

For any information, please contact:

www.fasep.it

e-mail:

[email protected]

FASEP 2000 srl
Via Faentina 96
50032 Ronta (Fi) Italy
Tel. #39 055 840 3126
Fax #39 055 840 3354

i

F

IG

.

  

1

 Balatron 210

F

IG

.

  

2

 Balatron 110

BALATRON B110, B210
USER

’S MANUAL

Summary of Contents for BALATRON B110

Page 1: ...nual 15 July 2013 For any information please contact www fasep it e mail info fasep it FASEP 2000 srl Via Faentina 96 50032 Ronta Fi Italy Tel 39 055 840 3126 Fax 39 055 840 3354 i FIG 1 Balatron 210...

Page 2: ...ence breakdown accidents due to unauthorized modifications of the unit use of non originalor unauthorizedaccessories see Accessories listing in this manualfor a list of originalaccessories available f...

Page 3: ...el Balancer 4 2 4 3 ALU SE Calibration 4 3 5 MEASUREMENT AND CORRECTION OF UNBALANCE 5 1 5 1 Placing the wheel rim on the wheel balancer 5 1 5 2 How to compensate unbalance of flanges using AFC functi...

Page 4: ...price of the unit and must be purchased separately This unit is designed for indoor use only see Environmental Data appendix for reference CAUTION This unit is designed to spin vehicle wheels only wi...

Page 5: ...ualified electrician 2 4 2 A fusible wall mounted switchbox is required at the installation site This switch should provide on off control and overload protection for your wheel balancer only The swit...

Page 6: ...e Special Functions MODE To select balancing type Dynamic Static Alu SET Confirm selection OPER To select Operator 1 or Operator 2 FINE To select reading scale FUNC To select specific functions START...

Page 7: ...ngs c indicated point of unbalance constantly wrong d more than 2 spins required to balance wheels repeatedly Switch on the wheel balancer Press SET when SOF X XX software version is displayed Place a...

Page 8: ...Wheel Balancer Switch on the wheel balancer Press SET when SOF X XX software version is displayed Press to select CAL TEST Place a wheel on the flange Fig 12 Press SET Hand spin the wheel Stop the wh...

Page 9: ...ly 2013 4 3 4 3 ALU SE Calibration Put the rod in 0 position Fig 15 Put the rod in internal side of flange Fig 16 Put the rod in the internal side of the rim Fig 17 Select the wheel diameter Press MOD...

Page 10: ...depend on proper performance of these procedures Clean accurately all cones shaft and adapter surface before placing the wheel on the wheel balancer CAUTION Always make sure flanges are correctly lock...

Page 11: ...in the same time Everyone can memorizes the dimensions of the wheel to balance with OPER button The machine memorizes the operating procedure too 5 3 1 DYNAMIC MODE Press MODE to select the operating...

Page 12: ...ating mode Select the wheel diameter Insert the internal measure IN 1 Fig 27 Fig 28 Insert the external measure IN 2 Fig 27 Fig 28 5 3 4 ALU SE 1 MODE ALU SE 2 MODE Automatic input optional Press MODE...

Page 13: ...spin stop the wheel The display will show the weight position and weight requirement to correct the wheel s umbalance 5 4 3 If unbalance shown is 0 press FINE to show residual unbalance G NOTE OPT lig...

Page 14: ...ust be put on the shaft in the same position as before Hand spin the wheel Left display 20 in example indicates present static unbalance Right display 55 in example indicates possible reduction of wei...

Page 15: ...alanceis calculated press FUNC toenter split function Turn the wheel until POS 1 is displayed Mark the tyre when the first spoke selected is at 12 o clock Turn the wheel until POS 2 is displayed Mark...

Page 16: ...els with diameter 11 from 11 to 17 Percent of wheels with the indicated diameter 17 0s Percent of wheels with diameter 17 CAL Number of calibrations 8 4 User Setup Switch on the wheel balancer Press S...

Page 17: ...umidity 5 at 95 to40 C Safety Features 1 The Balance Weights Holder may be removed for servicing It is secured to the machine body through screws so that only voluntarily it may be removed Removal of...

Page 18: ...ed FASEP 2000 Service Center C Errors and Malfunctions recognized by the Computer Errors may apply to some model only ERR 1 Shaft does not rotate ERR 16 Calibration memory error ERR 2 Rotation Directi...